Alkalinization of urine samples preserves albumin concentrations during prolonged frozen storage in patients with diabetes mellitus.

Lambers Heerspink HJ, Nauta FL, van der Zee CP, Brinkman JW, Gansevoort RT, de Zeeuw D, Bakker SJ

Publication: Diabet Med (2009) • Vol 26 • Page 556-9PMID: 19646198View on PubMed

Purpose

The purpose of this paper was to determine the effects of storage temperature, duration, and increasing pH prior to storage on urinary albumin concentration (UAC) and creatinine concentration.

Conclusion

Adjusting the pH of fresh urine specimens did not significantly change UAC or creatinine concentrations. Without adjustment of pH, storage of specimens at -20 degrees C for 7 d or 1 month had no effects on UAC, but after storage for 6 or 12 months, UAC significantly decreased. For specimens with adjusted pH, storage at -20 degrees C had no effects on UAC, regardless of storage duration. Further, storage of specimens at -80 degrees C, with or without adjustment of pH, had no effects on UAC, regardless of storage duration. Urinary creatinine concentrations were unaffected by storage at either temperature, regardless of duration or pH adjustment.

Studies (1)

Purpose

The purpose of this study was to determine the effects of storage temperature, duration, and increasing pH prior to storage on UAC and creatinine concentration. pH adjustment was accomplished by the addition of 1 M sodium hydroxide to urine specimens. Fresh urine was assayed after less than 2 h at room temperature. Only specimens with fresh UACs >5.0 mg/L were included in the study.

Summary of Findings

Adjusting the pH of fresh urine specimens (adjusted range 8.0-9.7, unadjusted range 4.8-7.4) did not significantly change UAC or creatinine concentrations. Without adjustment of pH, storage of specimens at -20 degrees C for 7 d or 1 month or -80 degrees C for up to 12 months had no effects on UAC, but UAC decreased after storage for 6 or 12 months at -20 degrees C. Baseline pH was significantly correlated with changes observed in UAC after 6 and 12 months of storage at -20 degrees C (R-squared=0.10, p<0.01 6 months, R-squared=0.18, p<0.01 12 months). For specimens with adjusted pH, storage at -20 degrees C or -80 degrees C had no effects on UAC, regardless of storage duration. Urinary creatinine concentrations were unaffected by storage at either temperature, regardless of duration or whether pH was adjusted or unadjusted.

  • Biospecimens

    FluidUrine
  • Preservation Types

    None (Fresh)Frozen
  • Diagnoses

    Diabetes Type 1
    Diabetes Type 2
  • Platforms

    ProteinClinical chemistry/auto analyzer
    Small moleculepH
  • Pre-analytical Factors

    ClassificationPre-Analytical FactorValue(s)
    Biospecimen Aliquots and ComponentspH
    < 8
    > 8
    Biospecimen PreservationType of fixation/preservation
    Frozen
    None (fresh)
    StorageStorage duration
    1 month
    12 months
    6 months
    7 d
    Less than 2 h
    StorageStorage temperature
    -20 degrees C
    -80 degrees C
    Room temperature