Pre-analytical operating procedures for serum Low Molecular Weight protein profiling.

Di Girolamo F, Alessandroni J, Somma P, Guadagni F

Publication: J Proteomics (2010) • Vol 73 • Page 667-77PMID: 19766745View on PubMed

Purpose

The purpose of this paper was to determine the effects of clotting time, storage temperature and duration, the addition of protease inhibitor, and manual versus automated peptide purification on low molecular weight serum proteome profiling.

Conclusion

Use of automated magnetic beads purification was found to be superior to manual magnetic beads purification. More spectral peaks were recovered when blood was left at room temperature to clot for 1-2 h as opposed to 30 min or 4 h prior to serum analysis. Serum could be stored for up to 2 h at room temperature or 3 h at 4 degrees C with minimal changes to proteome profiles as long as protease inhibitor was added to blood specimens. Without the added protease inhibitor, proteome profiles showed substantial changes with storage at either temperature for longer than 1 h. Storage of serum at -80 degrees C for 1 month resulted in only minimal changes to proteome profiles compared to those observed for fresh serum.

Studies (1)

Purpose

The purpose of this study was to determine the effects of clotting time, storage temperature and duration, the addition of protease inhibitor, and manual versus automated peptide purification on low molecular weight serum proteome profiling. The effects of the addition of protease inhibitor to blood on factor II and fibrinogen were also evaluated.

Summary of Findings

The addition of protease inhibitor had no effects on the coagulation cascade and all serum specimens were hemolysis-free. Use of automated magnetic beads purification resulted in the identification of 68 peaks with a coefficient of variation (CV) of 14.1% while use of manual magnetic beads purification lead to the identification of 57 spectral peaks with a CV of 18.2%. More spectral peaks were recovered when blood was left at room temperature to clot for 1-2 h as opposed to 30 min or 4 h prior to serum analysis. When whole blood was treated with protease inhibitor, storage of serum for up to 2 h at room temperature or 3 h at 4 degrees C prior to analysis resulted in minimal changes to serum proteomes compared to unstored serum, but longer storage at these temperatures resulted in considerable changes to the serum proteomes. When no protease inhibitor was added to whole blood, minimal changes to the serum proteomes were observed after storage of serum at room temperature or 4 degrees C for 1 h, but longer storage times at either temperature resulted in substantial changes to the proteome profiles. Storage of serum at -80 degrees C for 1 month resulted in only minimal changes to the proteome profiles compared to those observed for fresh serum.

  • Biospecimens

    FluidBlood
    FluidSerum
  • Preservation Types

    None (Fresh)
  • Diagnoses

    Normal
  • Platforms

    PeptideMALDI-TOF MS
    ProteinMALDI-TOF MS
    ProteinHematology/ auto analyzer
  • Pre-analytical Factors

    ClassificationPre-Analytical FactorValue(s)
    Biospecimen Aliquots and ComponentsCentrifugation
    Centrifugation delays investigated
    StorageStorage duration
    1 h
    1 month
    12 h
    2 h
    24 h
    3 h
    6 h
    StorageStorage temperature
    -80 degrees C
    4 degrees C
    Room temperature
    StorageTime at room temperature
    1 h
    2 h
    30 min
    4 h
    Analyte Extraction and PurificationAnalyte purification
    Automated magnetic beads purification
    Manual magnetic beads purification
    Analyte Extraction and PurificationProtease inhibitor
    EDTA-free
    No protease inhibitor added