Estimation of estrogen receptor content in fine-needle aspirates from breast cancer using the monoclonal antibody 1D5 and microwave oven processing: correlation with paraffin embedded and frozen sections determinations.
Schmitt FC, Bento MJ, Amendoeira I
Purpose
Conclusion
Studies (1)
Purpose
The purpose of this study was to determine the effects of antibody type and preservation method, and to compare surgically excised breast cancer specimens and FNA with respect to ER IHC staining results. The time period between fine needle aspiration and surgical excision ranged from 1-28 d. The ethanol-fixed FNA smears were processed in a microwave-oven.
Summary of Findings
When a 5 class scoring system was used (-, +, ++, +++, ++++) more intense staining was generally observed using the 1D5 antibody for ER IHC staining of ethanol-fixed FNA and formalin-fixed surgical excision specimens than when the H222 antibody was used for ER IHC staining of snap-frozen sections. With ER staining in snap-frozen sections taken as the standard and a two class scoring system, immunostaining in FNA showed a sensitivity of 95.4% and a specificity of 100% when 31 specimens were examined, while ER staining of formalin-fixed surgical specimens showed 100% sensitivity and specificity. The one discrepant FNA case was non-interpretable due to high background staining but was positive in both the formalin-fixed and snap-frozen sections.
Biospecimens
TissueBreastCellBreastPreservation Types
EthanolFormalinFrozenOther PreservativeDiagnoses
NeoplasticCarcinomaPlatforms
ProteinImmunohistochemistryMorphologyLight microscopyMorphologyH-and-E microscopyPre-analytical Factors
Classification Pre-Analytical Factor Value(s) Biospecimen Acquisition Method of tissue acquisition Fine needle aspirationSurgical resectionBiospecimen Preservation Type of fixation/preservation Air-driedEthanolFormalin (buffered)Snap frozenImmunohistochemistry Specific Type of antibody 1D5H222