Estimation of estrogen receptor content in fine-needle aspirates from breast cancer using the monoclonal antibody 1D5 and microwave oven processing: correlation with paraffin embedded and frozen sections determinations.

Schmitt FC, Bento MJ, Amendoeira I

Publication: Diagn Cytopathol (1995) • Vol 13 • Page 347-51PMID: 8599924View on PubMed

Purpose

The purpose of this paper was to compare estrogen receptor (ER) immunohistochemical (IHC) staining in surgically excised breast cancer specimens and fine needle aspirates.

Conclusion

Generally more intense staining was observed using the 1D5 antibody for ER IHC staining of ethanol-fixed FNA and formalin-fixed surgical excision specimens than when the H222 antibody was used for ER IHC staining of snap-frozen sections. With ER staining in snap-frozen sections taken as the standard, immunostaining in FNA showed a sensitivity of 95.4% and a specificity of 100% when 31 specimens were examined, while ER staining of formalin-fixed surgical specimens showed 100% sensitivity and specificity. The one discrepant FNA case was non-interpretable due to high background staining but was positive in both the formalin-fixed and snap-frozen sections.

Studies (1)

Purpose

The purpose of this study was to determine the effects of antibody type and preservation method, and to compare surgically excised breast cancer specimens and FNA with respect to ER IHC staining results. The time period between fine needle aspiration and surgical excision ranged from 1-28 d. The ethanol-fixed FNA smears were processed in a microwave-oven.

Summary of Findings

When a 5 class scoring system was used (-, +, ++, +++, ++++) more intense staining was generally observed using the 1D5 antibody for ER IHC staining of ethanol-fixed FNA and formalin-fixed surgical excision specimens than when the H222 antibody was used for ER IHC staining of snap-frozen sections. With ER staining in snap-frozen sections taken as the standard and a two class scoring system, immunostaining in FNA showed a sensitivity of 95.4% and a specificity of 100% when 31 specimens were examined, while ER staining of formalin-fixed surgical specimens showed 100% sensitivity and specificity. The one discrepant FNA case was non-interpretable due to high background staining but was positive in both the formalin-fixed and snap-frozen sections.

  • Biospecimens

    TissueBreast
    CellBreast
  • Preservation Types

    EthanolFormalinFrozenOther Preservative
  • Diagnoses

    NeoplasticCarcinoma
  • Platforms

    ProteinImmunohistochemistry
    MorphologyLight microscopy
    MorphologyH-and-E microscopy
  • Pre-analytical Factors

    ClassificationPre-Analytical FactorValue(s)
    Biospecimen AcquisitionMethod of tissue acquisition
    Fine needle aspiration
    Surgical resection
    Biospecimen PreservationType of fixation/preservation
    Air-dried
    Ethanol
    Formalin (buffered)
    Snap frozen
    Immunohistochemistry SpecificType of antibody
    1D5
    H222