Methodological aspects on microdialysis protein sampling and quantification in biological fluids: an in vitro study on human ventricular CSF.

Dahlin AP, Wetterhall M, Caldwell KD, Larsson A, Bergquist J, Hillered L, Hjort K

Publication: Anal Chem (2010) • Vol 82 • Page 4376-85PMID: 20465223View on PubMed

Purpose

The purpose of this paper was to determine the effects of perfusion fluid components and modification of microdialysis catheters on fluid recovery, protein adsorption and protein identification by isobaric tags for relative and absolute quantification (iTRAQ) labeling followed by MALDI-TOF mass spectrometry using cerebrospinal fluid (CSF).

Conclusion

Use of surface modified catheters with dextran 500 for microdialysis of CSF consistently resulted in close to 100% fluid recovery, less protein adsorption, and higher recoveries of hemopexin, beta hemoglobin, and transferrin.

Studies (1)

Purpose

The purpose of this study was to determine the effects of perfusion fluid components and modification of microdialysis catheters on fluid recovery, protein adsorption and protein identification by iTRAQ labeling followed by MALDI-TOF mass spectrometry in CSF from a patient with severe spontaneous subarachnoid hemorrhage. The effects were studied in vitro using CSF collected by ventricular drainage and stored frozen at -70 degrees C. Prior to microdialysis, the CSF was heated to 37 degrees C and equilibrated for 30 min.

Summary of Findings

When no dextran was added to the perfusion fluid, only 68% of the fluid was recovered through the surface modified catheter, and no fluid was recovered through the unmodified catheter. When the perfusion fluid contained 2-4% dextran 60, the fluid recovery was greater than 100%, regardless of catheter treatment, but addition of 3% dextran 250 or 500 resulted in superior fluid recovery rates of 105% and 99% for the untreated catheter and 89% and 98% for the surface modified catheter. The transmembrane flux and protein adsorption was lower when surface modified catheters were used for microdialysis than when untreated catheters were used, but the difference in transmembrane flux was only significant when the perfusion fluid contained dextran 60 or dextran 250. Importantly, the variability in fluid recovery between specimens was lower when dialyzed through a surface modified catheter. 48 proteins were identified by iTRAQ of which 16 were present across all preanalytical conditions. Albumin recovery was unaffected by dextran size, or catheter type. Clusterin and complement C3 recovery were not affected significantly by catheter modification. In contrast, recovery of hemopexin, beta hemoglobin, and transferrin were higher when microdialysis was with a surface modified catheter rather than an untreated catheter.
  • Biospecimens

    FluidCerebrospinal Fluid
  • Preservation Types

    Frozen
  • Diagnoses

    Other diagnoses
  • Platforms

    PeptideMALDI-TOF MS
    ProteinMALDI-TOF MS
    Cell count/volumeMacroscopic observation
  • Pre-analytical Factors

    ClassificationPre-Analytical FactorValue(s)
    PreaquisitionDiagnosis/ patient condition
    Severe spontaneous subarachnoid hemorrhage
    Biospecimen AcquisitionType of collection container/solution
    Pluronic F-127 surface modified catheter
    Untreated catheter
    Biospecimen Aliquots and ComponentsFiltration
    2%
    3%
    4%
    Dextran 250
    Dextran 500
    Dextran 60
    MALDI-TOF MS SpecificTargeted peptide/protein
    Albumin
    Beta hemoglobin
    Clusterin
    Complement C3
    Hemopexin
    Transferrin