The preanalytical influence of two different mechanical transport systems on laboratory analysis.

Koessler J, Kobsar AL, Brunner K, Stolz H, Dossler B, Walter U, Steigerwald U

Publication: Clin Chem Lab Med (2011) • Vol 49 • Page 1379-82PMID: 21574889View on PubMed

Purpose

The purpose of this paper was to determine the effects of transporting blood specimens via two mechanical transport systems, including a slow moving track vehicle system (TVS) and a rapid pneumatic tube system (PTS) rather than by courier transport (CT) on blood cell counts, coagulation parameters, platelet function tests, and clinical chemistry analytes.

Conclusion

The only significant difference observed between PTS and TVS transport was slightly elevated basal glycoprotein IIb/IIIa activation on platelet surface (PAC-1) activation in the PTS transported specimens. Similar basal PAC-1 activation levels were observed after TVS and CT transport. Activation of PAC-1 by adenosine diphosphate (ADP) was reduced after 2 and 5 min in PTS and TVS transported specimens compared to those transported by CT. In addition, the number of leukocytes and lymphocytes were reduced, and lactate dehydrogenase (LD), aspartate transamine (AST) (TVS only), prothrombin time (PT), and d-dimer concentration were each significantly increased in specimens transported by PTS and TVS compared to those transported by CT. 21 other analytes were unaffected by specimen transportation method.

Studies (1)

Purpose

The purpose of this study was to determine the effects of TVS and PTS as methods for transport of blood specimens compared to courier transport (CT) on blood cell counts, coagulation parameters, platelet function tests, and clinical chemistry analytes. Specimens were collected from 33 volunteers including healthy individuals, and those on oral anticoagulants or other medications. Specimens were collected into different tube types but no comparison is made.

Summary of Findings

The only significant difference observed between PTS and TVS transport was slightly elevated basal PAC-1 activation in the PTS transported specimens. Similar basal PAC-1 activation levels were observed after TVS and CT transport. Activation of PAC-1 by ADP was reduced after 2 and 5 min in PTS and TVS transported specimens compared to those transported by CT. The number of leukocytes and lymphocytes were reduced after PTS or TVS transport compared to CT, but the reduction was only significant for leukocytes when blood was transported by PTS. LD was significantly increased after transport of blood specimens by PTS or TVS compared to CT. AST was significantly increased in the TVS transported specimens compared to those transported by CT, but not in the PTS transported specimens. PT and d-dimer concentration were each significantly increased in specimens transported by PTS and TVS compared to those transported by CT. 21 other analytes were unaffected by specimen transportation method.
  • Biospecimens

    FluidBlood
  • Preservation Types

    None (Fresh)
  • Diagnoses

    Normal
    Not specified
  • Platforms

    Cell count/volumeHematology/ auto analyzer
    ProteinHematology/ auto analyzer
    MorphologyHematology/ auto analyzer
    PeptideHematology/ auto analyzer
    ProteinClinical chemistry/auto analyzer
    Electrolyte/MetalClinical chemistry/auto analyzer
  • Pre-analytical Factors

    ClassificationPre-Analytical FactorValue(s)
    Biospecimen AcquisitionAnticoagulant
    Citrate
    EDTA
    Gel-barrier
    StorageSpecimen transport duration/condition
    1 min 45 sec (PTS)
    11 min (TVS)
    4 min (hand-delivered)
    StorageWithin hospital transportation method
    Hand-delivered
    Pneumatic tube system
    Track vehicle system