Skip to main content

Application of tissue microarray technology to the study of non-Hodgkin's and Hodgkin's lymphoma.

Hedvat CV, Hegde A, Chaganti RS, Chen B, Qin J, Filippa DA, Nimer SD, Teruya-Feldstein J

Publication: Hum Pathol (2002) • Vol 33 • Page 968-74PMID: 12395368View on PubMed

Purpose

The purpose of this paper was to determine the effects of immunohistochemical (IHC) staining of tissue microarray (TMA) versus whole section slides to evaluate lymphoma specimens. In addition, in situ hybridization (ISH) and IHC methods were compared for the detection of Epstein-Barr virus (EBV).

Conclusion

In almost all cases, IHC staining of CD30, cyclin-D1, CD5, CD3, CD10 and CD20 yielded the same results on TMA and whole section slides. Bcl-2, CD23, and CD43 IHC staining results had lower concordance rates and agreement (86-88%) between TMA and whole section slides. False negatives obtained by staining TMA sections accounted for 70% of the discrepant results. When the presence of EBV was detected by IHC staining for latent membrane protein 1 (LMP1) and by ISH using probes for EBER-1 and EBER-2, similar results were obtained by IHC and ISH for 26 of 27 specimens.

Studies (1)

Purpose

The purpose of this study was to determine the effects of IHC staining of TMA versus whole section slides to evaluate protein expression in lymphoma specimens. In addition, ISH and IHC methods were compared for the detection of EBV. 2-3 cores for each specimen were on the TMA. When discrepancies were noted between two cores on the same TMA, the authors report the higher value.

Summary of Findings

Between 21 and 55 TMA and whole section slides were examined by IHC for each antibody. In almost all cases, CD30, cyclin-D1, CD5, CD3, and CD20 IHC staining results were the same on TMA and whole section slides. CD10 staining also showed 95% agreement between slide types. However, Bcl-2, CD23, and CD43 IHC staining results had lower concordance rates and agreement (K=0.66, 88% agreement; K=0.53, 86% agreement; and K=0.77, 88% agreement, respectively) between TMA and whole section slides. False negatives obtained by staining TMA sections accounted for 70% of the discrepant results. When the presence of EBV was detected by IHC staining for LMP1 and by ISH using probes for EBER-1 and EBER-2, similar results were obtained by ISH and IHC for 26 of 27 specimens. The discrepant case was EBV+ by IHC and EBV- by ISH.

  • Biospecimens

    TissueLymph Node
    TissueSpleen
    TissueTonsil
    TissueThymus Gland
  • Preservation Types

    FormalinOther Preservative
  • Diagnoses

    Normal
    NeoplasticLymphoma
  • Platforms

    ProteinImmunohistochemistry
    ProteinTissue microarray
    RNAIn situ hybridization
  • Pre-analytical Factors

    ClassificationPre-Analytical FactorValue(s)
    Biospecimen AcquisitionBiospecimen location
    Lymph node
    Spleen
    Thymus
    Tonsil
    Biospecimen Aliquots and ComponentsType of slide
    Tissue microarray
    Whole section
    Biospecimen PreservationType of fixation/preservation
    B-3 fixative
    Formalin (buffered)
    In situ hybridization SpecificTargeted nucleic acid
    EBER-1
    EBER-2
    In situ hybridization SpecificTechnology platform
    Immunohistochemistry
    Immunohistochemistry SpecificTargeted peptide/protein
    Bcl-2
    CD10
    CD20
    CD23
    CD3
    CD30
    CD43
    CD5
    Cyclin D1
    LMP1