The effect of sodium citrate in arterial catheters on acid-base and electrolyte measurements.
Cardinal P, Allan J, Pham B, Hindmarsh T, Jones G, Delisle S
Purpose
The purpose of this paper was to determine the effects of anticoagulant type in the sampling catheter on clinical chemistry analytes in arterial blood.
Conclusion
When the first 2 mL of blood were discarded, only calcium, pH and glucose levels were affected by the type of anticoagulant contained in the sampling catheter. Generally, after discarding the first 2-3 mL, anticoagulation with heparin inside the catheter did not significantly affect calcium, pH or glucose levels, but collection of blood through catheters containing sodium citrate led to significantly decreased calcium levels, decreased pH, and elevated glucose levels compared to specimens collected by arterial puncture without anticoagulant.
Studies (1)
Purpose
The purpose of this study was to determine the effects of type of anticoagulant in the catheter used to collect blood specimens on clinical chemistry analytes in sequentially drawn aliquots of blood. Ten 1 mL aliquots of blood were obtained through an arterial catheter containing heparin or sodium citrate and an additional specimen was collected by arterial puncture. All specimens were stored on ice for up to 60 min prior to analysis.
Summary of Findings
Partial pressure oxygen (PO2), lactate, and sodium did not vary between specimens collected through catheters containing heparin or sodium citrate, but calcium, pH, glucose, partial pressure carbon dioxide (pCO2) chloride and potassium levels were affected by anticoagulant in the catheter as well as specimen sequential collection. When blood was collected through a catheter containing sodium citrate, calcium levels were decreased by more than 20% in all aliquots compared to non-anticoagulated arterial blood. However, when blood was collected through a catheter containing heparin, only a 2.2% decrease was found after the first 2 mL of blood were discarded compared to arterial blood collected without anticoagulant. Use of catheters containing sodium citrate led to a more than 5% decrease in pH for all specimens compared to arterial blood collected without anticoagulant, but after discarding the first mL, this difference was eliminated. When blood was collected through catheters containing sodium citrate, glucose levels were more than 6% higher in all aliquots than in arterial blood collected without anticoagulant, but when collected through a catheter containing heparin, there was a slight reduction in glucose in all aliquots compared to arterial blood collected without anticoagulant. Importantly, after the first 3 mL of blood collected through a catheter containing heparin were discarded, glucose levels were in the clinically expected range. Collection of blood through catheters containing sodium citrate led to increased pCO2 compared to arterial blood collected without anticoagulant, but those containing heparin led to decreased pCO2 compared to arterial blood collected without anticoagulant; however, the magnitude of the change was similar between anticoagulants and, after discarding the first 2 mL, was not significant. Chloride and potassium levels were unaffected by anticoagulant in the catheter after the first 2 mL were discarded.
Biospecimens
FluidBloodPreservation Types
None (Fresh)Diagnoses
Not specifiedPlatforms
CarbohydrateClinical chemistry/auto analyzerElectrolyte/MetalClinical chemistry/auto analyzerGasClinical chemistry/auto analyzerSmall moleculeClinical chemistry/auto analyzerPre-analytical Factors
Classification Pre-Analytical Factor Value(s) Biospecimen Acquisition Anticoagulant HeparinSodium citrateBiospecimen Aliquots and Components Aliquot sequential collection 10th collection1st collection2nd collection3rd collection4th collection5th collection6th collection7th collection8th collection9th collection