Skip to main content

How and how long to store urine samples before albumin radioimmunoassay: a practical response.

Giampietro O, Penno G, Clerico A, Cruschelli L, Cecere M

Publication: Clin Chem (1993) • Vol 39 • Page 533-6PMID: 8448872View on PubMed

Purpose

The purpose of this paper was to determine the effects of storage temperature, duration, and container on the stability of urinary albumin.

Conclusion

No differences in albumin concentration were observed between specimens stored in glass, polystyrene, or polypropylene tubes at -20 degrees C over the course of 2 months. Compared to measurements taken on urine within 1 hour of collection, storage of urine at room temperature for 24 h, 4 degrees C for 24 or 72 h, or -20 degrees C for up to 2 months did not significantly affect albumin concentration, but urinary albumin concentration was decreased when urine was stored at -20 degrees C for 2 y or 4-5 y.

Studies (1)

Purpose

The purpose of this study was to determine the effects of storage temperature, duration, and container on the stability of urinary albumin. 21 pooled urine specimens were used to determine the stability of albumin at -20 degrees C over a period of 4-21 months. All other storage conditions and durations were investigated using individual urine specimens which were also assayed prior to storage.

Summary of Findings

No differences in albumin concentration were observed between specimens stored in glass, polystyrene, or polypropylene tubes at -20 degrees C over the course of 2 months. Storage of urine at room temperature for 24 h, 4 degrees C for 24 or 72 h, or -20 degrees C for up to 2 months did not significantly affect albumin concentration compared to measurements taken on urine within 1 hour of collection. Significant decreases in urinary albumin concentration were observed when urine was stored at -20 degrees C for 2 y (-13.2%) or 4-5 y (-21.8%) compared to concentrations measured prior to the long-term storage. When pooled urine was repeatedly assayed during storage at -20 degrees C, 3 of 21 pools showed significant decreases in albumin concentration over the course of 4-21 months.

  • Biospecimens

    FluidUrine
  • Preservation Types

    None (Fresh)FrozenOther Preservative
  • Diagnoses

    Normal
    Diabetes Type 1
    Diabetes Type 2
  • Platforms

    ProteinRadioimmunoassay
  • Pre-analytical Factors

    ClassificationPre-Analytical FactorValue(s)
    PreaquisitionBiomarker level
    Macroalbuminuric
    Microalbuminuric
    Normo-albuminuric
    Biospecimen PreservationType of fixation/preservation
    Frozen
    None (fresh)
    Refrigeration
    StorageStorage duration
    1 h
    14 d
    2 y
    21 d
    24 h
    24 h
    28 d
    4-21 months
    4-5 y
    60 d
    7 d
    72 h
    StorageStorage temperature
    -20 degrees C
    18-20 degrees C
    4 degrees C
    StorageType of storage container
    Glass
    Polypropylene
    Polystyrene