Potassium levels in serum and plasma.
Pannall P, Rossi A
Purpose
Conclusion
Studies (1)
Purpose
The purpose of this study was to determine the effects of analyzing plasma rather than serum on the measurement of potassium in 81 blood specimens. Blood was separated within 1.5 h, and any visibly hemolyzed specimens were excluded.
Summary of Findings
In 89 of the 95 comparisons, the serum potassium level was an average of 35 mequiv/L higher than the plasma level. Of 15 patients with potassium levels below the normal range in plasma, only 2 had levels below the normal range in serum. Of 7 serum specimens with potassium levels above the normal range, 5 had matched plasma specimens that also had high potassium levels. The daily variation in the difference between serum and plasma potassium levels was much less than the variation between patients, but the 4 patients included in this analysis were not sufficient for statistical significance.
Biospecimens
FluidPlasmaFluidSerumFluidBloodPreservation Types
None (Fresh)Diagnoses
Not specifiedPlatforms
Electrolyte/MetalFlame emission photometryPre-analytical Factors
Classification Pre-Analytical Factor Value(s) Biospecimen Acquisition Anticoagulant Lithium heparinNoneBiospecimen Acquisition Time of biospecimen collection Day 1Day 2Day 3Day 4Biospecimen Aliquots and Components Blood and blood products PlasmaSerum