Effects of anticoagulants on acid-base and blood gas determinations
Goodwin NM, Schreiber MT
Purpose
Conclusion
Studies (1)
Purpose
The purpose of this study was to determine the effects of anticoagulant type and concentration on blood gas and pH measurements in blood specimens. Arterial blood specimens were collected into syringes containing anticoagulants in the dead space. In some cases, an additional 0.5 mL of anticoagulant was added. All specimens were stored on ice for less than 30 min prior to analysis.
Summary of Findings
Anticoagulation with EDTA significantly reduced pH, increased the PO2, and consequently increased the calculated bicarbonate and base excess compared to the expected values. The highest concentration of heparin (25000 IU/mL) only decreased the PCO2 by 4%, while lower concentrations of heparin decreased PCO2 by 16%, and trisodium citrate and oxalate decreased PCO2 by 8-10% when expected values were taken as the baseline. When specimens were anticoagulated with 25000 IU/mL heparin or an excess volume of citrate, the pH was reduced. PO2 measurements were unaffected by anticoagulants other than EDTA. Generally, dilution of the specimen by adding an additional 0.5 mL anticoagulant had little effect on pH but decreased PCO2 resulting in lower calculated bicarbonate and higher calculated base excess compared to the smaller concentration of the same anticoagulant.
Biospecimens
FluidBloodPreservation Types
None (Fresh)Diagnoses
NormalPlatforms
Small moleculepHGasClinical chemistry/auto analyzerPre-analytical Factors
Classification Pre-Analytical Factor Value(s) Biospecimen Acquisition Anticoagulant EDTAHeller-Paul oxalateHeparinMultiple concentrations evaluatedSodium citrate