Maximizing RNA yield from archival renal tumors and optimizing gene expression analysis.
Glenn ST, Head KL, Teh BT, Gross KW, Kim HL
Purpose
The purpose of this paper was to optimize RNA extraction and real-time PCR amplification from formalin-fixed paraffin-embedded (FFPE) renal carcinoma specimens.
Conclusion
The highest RNA yield and least DNA contamination were obtained from renal specimens using the MasterPure kit. Extending the proteinase k digestion time from 3 h to overnight increased RNA yield, and using gene-specific primers for reverse transcription rather than random primers decreased the average cycle threshold (CT) by 2. Using custom TaqMan low density arrays instead of conventional 384 well plates, or a BioRad CFX 384 instead of an ABI 7900HT for real-time PCR, resulted in higher CTs which, in some cases, affected detectability.
Studies (1)
Purpose
The purpose of this study was to determine the effects of RNA isolation and quantification methods and real-time PCR parameters on RNA yield and subsequent amplification from FFPE renal carcinoma specimens. RNA was extracted from 3 sections of FFPE renal tumors from each of 10 patients.
Summary of Findings
No difference in measured RNA yield was found when quantification was performed using RiboGreen rather than a Nanodrop spectrophotometer, and levels correlated highly with the beta actin (ACTB) cycle threshold (CT). The highest RNA yield was obtained using the MasterPure kit compared to the RecoverAll, High Pure FFPE, or ArrayGrade FFPE kits, but the yield was not significantly higher than when extraction was with Trizol. The RecoverAll and ArrayGrade kits yielded approximately 50% as much RNA as the MasterPure kit and the Highpure kit yielded less than 30% as much RNA. The RNA extracted using MasterPure kit was also free from DNA contamination, while RNA extracted using each of the other kits required a second DNAse treatment for one specimen, and 3 specimens required further treatment using the Trizol method. Extending the proteinase k digestion time from 3 h to overnight increased RNA yield when specimens were extracted with either the MasterPure kit, Trizol, or the RecoverAll kit. When reverse transcription was performed using gene-specific primers, the average CT was 2 lower than when reverse transcription was performed with random primers, but the relative abundance of the 23 assayed transcripts was not altered. Using custom TaqMan low density arrays instead of conventional 384 well plates, or a BioRad CFX 384 instead of an ABI 7900HT for real-time PCR, resulted in higher CTs which, in some cases, affected detectability.
Biospecimens
TissueKidneyPreservation Types
FormalinDiagnoses
NeoplasticCarcinomaPlatforms
RNAFluorometryRNASpectrophotometryRNAReal-time qRT-PCRRNALow density arrayPre-analytical Factors
Classification Pre-Analytical Factor Value(s) Analyte Extraction and Purification Analyte isolation method Xylene deparaffinization, proteinase k digestion and trizol extractionArrayGrade FFPE kitHigh Pure FFPE kitMasterPure kitRecoverAll kitAnalyte Extraction and Purification Nucleic acid digestion OnceTwiceAnalyte Extraction and Purification Protein digestion 3 hOvernightReal-time qRT-PCR Specific Priming method Gene-specificRandomReal-time qRT-PCR Specific Technology platform ABI 7900BioRad CFX384Real-time qRT-PCR Specific Type of array 384 well plateTaqMan low density arraySpectrophotometry Specific Technology platform NanodropRiboGreen