Cholesterol determinations from skin puncture and venous blood have similar imprecisions.
Dörner K, Dorn-Zachertz D
Purpose
Conclusion
Studies (1)
Purpose
The purpose of this study was to determine the effect of collecting blood by skin puncture versus venipuncture on cholesterol and urea levels in plasma. 12 healthy volunteers were asked to sit for 5 minutes prior to having the skin punctured on the tips of the 2nd-5th fingers of both hands. Immediately following collection of the skin puncture blood in heparinized microtainers, venous blood was drawn and transferred to heparinized microtainers.
Summary of Findings
Cholesterol levels were an average of 3.9% lower in skin puncture plasma than in venipuncture plasma, but the difference was not significant. The difference in average urea levels between skin puncture and venipuncture plasma was less than 0.5% and fell within the analytical error. More variability was found in urea levels (1.88%) between specimens of the same type than in cholesterol levels (1.38%). Further, more variability between specimens was found when plasma was obtained by skin puncture rather than venipuncture, but the difference was significant for only 4 individuals.
Biospecimens
FluidBloodFluidPlasmaPreservation Types
None (Fresh)Diagnoses
NormalPlatforms
SteroidClinical chemistry/auto analyzerSmall moleculeClinical chemistry/auto analyzerPre-analytical Factors
Classification Pre-Analytical Factor Value(s) Biospecimen Acquisition Anatomical location of blood draw CapillaryVeinBiospecimen Acquisition Method of fluid acquisition Finger/heel prick samplingVenipuncture