Skip to main content

Cholesterol determinations from skin puncture and venous blood have similar imprecisions.

Dörner K, Dorn-Zachertz D

Publication: Eur J Clin Chem Clin Biochem (1991) • Vol 29 • Page 411-3PMID: 1912092View on PubMed

Purpose

The purpose of this paper was to determine the effect of collecting blood by skin puncture rather than venipuncture on the variability of measured cholesterol and urea levels in plasma.

Conclusion

A non-significant decrease in measured cholesterol levels was observed in skin puncture plasma compared to venipuncture plasma, but there was no effect of collection method on urea levels. Generally, more inter-specimen variability was found in skin puncture than venipuncture plasma.

Studies (1)

Purpose

The purpose of this study was to determine the effect of collecting blood by skin puncture versus venipuncture on cholesterol and urea levels in plasma. 12 healthy volunteers were asked to sit for 5 minutes prior to having the skin punctured on the tips of the 2nd-5th fingers of both hands. Immediately following collection of the skin puncture blood in heparinized microtainers, venous blood was drawn and transferred to heparinized microtainers.

Summary of Findings

Cholesterol levels were an average of 3.9% lower in skin puncture plasma than in venipuncture plasma, but the difference was not significant. The difference in average urea levels between skin puncture and venipuncture plasma was less than 0.5% and fell within the analytical error. More variability was found in urea levels (1.88%) between specimens of the same type than in cholesterol levels (1.38%). Further, more variability between specimens was found when plasma was obtained by skin puncture rather than venipuncture, but the difference was significant for only 4 individuals.

  • Biospecimens

    FluidBlood
    FluidPlasma
  • Preservation Types

    None (Fresh)
  • Diagnoses

    Normal
  • Platforms

    SteroidClinical chemistry/auto analyzer
    Small moleculeClinical chemistry/auto analyzer
  • Pre-analytical Factors

    ClassificationPre-Analytical FactorValue(s)
    Biospecimen AcquisitionAnatomical location of blood draw
    Capillary
    Vein
    Biospecimen AcquisitionMethod of fluid acquisition
    Finger/heel prick sampling
    Venipuncture