Skip to main content

Prolonged frozen storage of urine reduces the value of albuminuria for mortality prediction.

Brinkman JW, de Zeeuw D, Gansevoort RT, Duker JJ, Kema IP, de Jong PE, Bakker SJ

Publication: Clin Chem (2007) • Vol 53 • Page 153-4PMID: 17202507View on PubMed

Purpose

The purpose of this paper was to determine the effects of long term frozen storage and day to day variation of urinary albumin concentrations (UAC) in fresh and frozen specimens.

Conclusion

After 7 y of storage at -20 degrees C, the average percentage decrease in UAC was 17-30%, depending on the initial UAC. Specimens collected on consecutive days showed variations of 16-26% for fresh specimens and 23-40% for frozen specimens. The average percentage change in UAC during long term frozen storage and between collection days was the largest for specimens initially falling in the 10-20 and 20-200 mg/L ranges. The authors highlight there was a significant decrease in the predictive properties of albuminuria with respect to mortality after specimens were stored for 7 y at -20 degrees C compared to the predictive properties of albuminuria for mortality of fresh specimens.

Studies (1)

Purpose

The purpose of this study was to determine the effects of storing urine specimens at -20 degrees C for 7 years on UAC and to determine day to day variation in UAC of fresh and frozen specimens.

Summary of Findings

Fresh specimens contained a median UAC of 5.0 mg/L. But after approximately 7 y of storage at -20 degrees C, the average percentage decrease in UAC was 17-30%, depending on the initial UAC. Specimens collected on consecutive days showed variations of 16-26% for fresh specimens and 23-40% for frozen specimens. The average percentage change in UAC during long term frozen storage and between collection days was the largest for specimens initially falling in the 10-20 and 20-200 mg/L ranges. The authors highlight there was a significant decrease in the predictive properties of albuminuria with respect to mortality after specimens were stored for 7 y at -20 degrees C compared to fresh specimens.

  • Biospecimens

    FluidUrine
  • Preservation Types

    FrozenNone (Fresh)
  • Diagnoses

    Other diagnoses
  • Platforms

    ProteinClinical chemistry/auto analyzer
  • Pre-analytical Factors

    ClassificationPre-Analytical FactorValue(s)
    PreaquisitionBiomarker level
    10-20 mg/L UAC
    20-200 mg/L UAC
    <10 mg/L UAC
    >200 mg/L UAC
    PreaquisitionDiagnosis/ patient condition
    Albuminuria
    Biospecimen Aliquots and ComponentsAliquot sequential collection
    1st collection
    2nd collection
    Biospecimen PreservationType of fixation/preservation
    Frozen
    None (fresh)
    StorageStorage duration
    0 y
    7 y