Skip to main content

Simultaneously obtained skin-puncture serum, skin-puncture plasma, and venous serum compared, and effects of warming the skin before puncture.

Blumenfeld TA, Hertelendy WG, Ford SH

Publication: Clin Chem (1977) • Vol 23 • Page 1705-10PMID: 890915View on PubMed

Purpose

The purpose of this paper was to determine the effects of blood collection method and the use of serum rather than plasma on the measurement of 15 clinical chemistry analytes in blood.

Conclusion

Clinically relevant lower levels of potassium, calcium and total protein and higher levels of glucose were measured in plasma and serum after skin puncture compared to plasma obtained after venipuncture. No clinically significant differences were observed between serum and plasma collected through skin puncture. Warming of the hands did not affect the levels of any of the clinical chemistry analytes in plasma or serum collected by skin puncture.

Studies (1)

Purpose

The purpose of this study was to determine the effects of blood collection method, including hand warming prior to skin puncture, and the use of serum rather than ammonium heparin plasma on the measurement of 15 clinical chemistry analytes in blood from healthy individuals. Skin temperature was increased by applying warmed surgical dressings to the hands for 3 min prior to skin puncture. Serum was collected into serum separator tubes (SST).

Summary of Findings

Lactate dehydrogenase (LDH), alkaline phosphatase, urea nitrogen, calcium, chloride, free hemoglobin, glucose and potassium levels were similar in plasma and serum collected through skin puncture. However, significant but clinically irrelevant depressions in magnesium and sodium as well as elevations in phosphorous levels were observed in serum compared to plasma collected through skin puncture. Lower levels of potassium, calcium and total protein that were clinically and statistically significant were observed in plasma and serum collected through skin puncture compared to plasma collected through venipuncture. Clinically relevant but statistically insignificant increases in glucose were found in plasma and serum collected through skin puncture compared to plasma collected by venipuncture. Free hemoglobin was significantly lower when specimens were collected by venipuncture than by skin puncture, but the difference was judged to be clinically irrelevant. There were no differences in levels of LDH, alkaline phosphatase, urea nitrogen, chloride, magnesium, and phosphorous between specimens collected by skin puncture and venipuncture. Warming of the hands to 37-37.5 degrees C from 34-35 degrees C did not affect the levels of any of the clinical chemistry analytes in serum or plasma collected by skin puncture.

  • Biospecimens

    FluidPlasma
    FluidSerum
    FluidBlood
  • Preservation Types

    None (Fresh)
  • Diagnoses

    Normal
  • Platforms

    CarbohydrateClinical chemistry/auto analyzer
    Electrolyte/MetalClinical chemistry/auto analyzer
    Electrolyte/MetalFlame emission photometry
    ProteinClinical chemistry/auto analyzer
    Small moleculeClinical chemistry/auto analyzer
    ProteinSpectrophotometry
  • Pre-analytical Factors

    ClassificationPre-Analytical FactorValue(s)
    Biospecimen AcquisitionAnatomical location of blood draw
    Capillary
    Vein
    Biospecimen AcquisitionMethod of fluid acquisition
    Finger/heel prick sampling
    Finger/heel prick with warming
    Venipuncture
    Biospecimen Aliquots and ComponentsBlood and blood products
    Plasma