Influence of heparinization on pH determination from arterial blood
Bech-Jenson P, Beck O
Publication: Acta anaesth scand (1972) • Vol 16 • Page 35-37
Purpose
The purpose of this paper was to determine the effects of heparin concentration on the pH of blood specimens.
Conclusion
Blood pH increased when heparin concentrations were increased as a result of smaller blood volumes or higher concentrations of heparin used, however, the effect of blood volume plateaued at a 0.7 mL or smaller fill volume and was less evident when 100 or 1000 IU/mL heparin was used.
Studies (1)
Purpose
The purpose of this study was to determine the effects of heparin concentration on the pH of blood specimens. Blood was collected from the femoral artery of 15 anesthetized patients into glass syringes with heparin LEO 25,000 IU/mL in the dead space and then transferred in volumes ranging from 0.1-10 mL into Mantoux syringes containing heparin diluted to 100-10,000 IU/mL with saline.
Summary of Findings
Blood pH increased when blood volume increased resulting in dilution of the heparin to lower concentrations, but for all concentrations of heparin evaluated, the effect of volume plateaued at a fill volume of 0.7 mL blood or more. Blood volume had the strongest effects on pH when the specimens were collected in tubes containing 0.1 mL of 5000 IU/mL heparin. Blood volume effects were negligible when 0.6 mL-1.0 mL of blood was transferred to tubes containing 0.1 mL of 100 or 1,000 IU/mL heparin.
Biospecimens
FluidBloodPreservation Types
None (Fresh)Diagnoses
Not specifiedPlatforms
Small moleculepHPre-analytical Factors
Classification Pre-Analytical Factor Value(s) Biospecimen Acquisition Anticoagulant HeparinMultiple concentrations evaluatedBiospecimen Aliquots and Components Aliquot size/volume 0.1 mL0.2 mL0.3 mL0.4 mL0.5 mL0.6 mL0.7 mL0.8 mL0.9 mL1.0 mL10 mL