Skip to main content

Influence of heparinization on pH determination from arterial blood

Bech-Jenson P, Beck O

Publication: Acta anaesth scand (1972) • Vol 16 • Page 35-37

Purpose

The purpose of this paper was to determine the effects of heparin concentration on the pH of blood specimens.

Conclusion

Blood pH increased when heparin concentrations were increased as a result of smaller blood volumes or higher concentrations of heparin used, however, the effect of blood volume plateaued at a 0.7 mL or smaller fill volume and was less evident when 100 or 1000 IU/mL heparin was used.

Studies (1)

Purpose

The purpose of this study was to determine the effects of heparin concentration on the pH of blood specimens. Blood was collected from the femoral artery of 15 anesthetized patients into glass syringes with heparin LEO 25,000 IU/mL in the dead space and then transferred in volumes ranging from 0.1-10 mL into Mantoux syringes containing heparin diluted to 100-10,000 IU/mL with saline.

Summary of Findings

Blood pH increased when blood volume increased resulting in dilution of the heparin to lower concentrations, but for all concentrations of heparin evaluated, the effect of volume plateaued at a fill volume of 0.7 mL blood or more. Blood volume had the strongest effects on pH when the specimens were collected in tubes containing 0.1 mL of 5000 IU/mL heparin. Blood volume effects were negligible when 0.6 mL-1.0 mL of blood was transferred to tubes containing 0.1 mL of 100 or 1,000 IU/mL heparin.
  • Biospecimens

    FluidBlood
  • Preservation Types

    None (Fresh)
  • Diagnoses

    Not specified
  • Platforms

    Small moleculepH
  • Pre-analytical Factors

    ClassificationPre-Analytical FactorValue(s)
    Biospecimen AcquisitionAnticoagulant
    Heparin
    Multiple concentrations evaluated
    Biospecimen Aliquots and ComponentsAliquot size/volume
    0.1 mL
    0.2 mL
    0.3 mL
    0.4 mL
    0.5 mL
    0.6 mL
    0.7 mL
    0.8 mL
    0.9 mL
    1.0 mL
    10 mL