Skip to main content

Clinical chemical analyses of serum obtained from capillary versus venous blood, using Microtainers and Vacutainers.

Falch DK

Publication: Scand J Clin Lab Invest (1981) • Vol 41 • Page 59-62PMID: 7256193View on PubMed

Purpose

The purpose of this paper was to determine the effects of collecting serum by skin puncture rather than venipuncture on clinical chemistry determinants.

Conclusion

Sodium, calcium, phosphorous, creatinine, and total protein were lower and potassium, chloride, and thyroid-stimulating hormone (TSH) were higher in serum collected by skin puncture instead of venipuncture, but the effects on sodium, calcium and TSH levels were attributed to collection into a microtainer rather than a vacutainer. Collection method had no effects on urea, bilirubin, L-alanine aminotransferase (ALAST), L-aspartate aminotransferase (ASAT), lactate dehydrogenase (LD), insulin or thyroxin. Growth hormone levels were unaffected by collection method in 3 of 9 patients and were below the limit of detection in the remaining 6.

Studies (1)

Purpose

The purpose of this study was to determine the effects of collection method and container on the levels of clinical chemistry analytes in serum. Skin puncture blood was collected into a microtainer, while venipuncture blood was collected into a vacutainer.

Summary of Findings

Sodium, calcium, phosphorous, creatinine, and total protein were lower in serum collected by skin puncture than by venipuncture. In contrast, potassium, chloride, and TSH were higher in serum collected by skin puncture instead of venipuncture. Collection method had no effects on urea, bilirubin, ALAST, ASAT, LD, insulin or thyroxin. Growth hormone levels were unaffected by collection method in 3 of 9 patients and were below the limit of detection in the remaining 6. When blood was collected by venipuncture and then transferred to a microtainer, sodium and calcium levels were decreased and TSH was increased compared to the aliquot of the specimen kept in the vacutainer, indicating the effects for these three analytes were tube dependent, not collection method dependent.

  • Biospecimens

    FluidSerum
    FluidBlood
  • Preservation Types

    None (Fresh)
  • Diagnoses

    Not specified
    Normal
  • Platforms

    Electrolyte/MetalClinical chemistry/auto analyzer
    GlycoproteinRadioimmunoassay
    Small moleculeClinical chemistry/auto analyzer
    ProteinClinical chemistry/auto analyzer
    ProteinRadioimmunoassay
    PeptideRadioimmunoassay
  • Pre-analytical Factors

    ClassificationPre-Analytical FactorValue(s)
    Biospecimen AcquisitionAnatomical location of blood draw
    Capillary
    Vein
    Biospecimen AcquisitionMethod of fluid acquisition
    Finger/heel prick sampling
    Venipuncture
    Biospecimen AcquisitionType of collection container/solution
    Microtainer
    Vacutainer