A method of rapid fixation of large biopsy specimens using microwave irradiation.
Leong AS, Duncis CG
Purpose
Conclusion
Studies (1)
Purpose
The purpose of this study was to compare morphological preservation between large surgical specimens from 16 tissues that underwent microwave fixation in saline with those that were immersed in formalin. In addition, heating specimens in formalin or saline using an open flame was evaluated for fixation potential.
Summary of Findings
Microwave irradiation of large surgical specimens in saline for 4-9 min, trimming, and additional microwave exposure for 4-7 min to a temperature of 67-74 degrees C yielded H&E staining comparable to immersion in formalin at room temperature for 12-18 h. Heating specimens in formalin or saline to 67-74 degrees C using an open flame did not sufficiently harden tissue to be practical. Microwave-fixed specimens were able to be processed in an autoprocessor without formalin in 3 h 15 min compared with formalin-fixed specimens which were processed in 13 h with additional formalin in the autoprocessor.
Biospecimens
TissueThyroid GlandTissueTestisTissueTonsilTissueLungTissueKidneyTissueUterusTissueOvaryTissueSpleenTissueSkinTissueEsophagusTissueStomachTissueSmall BowelTissueColorectalTissueBreastTissueGall BladderTissueLiverPreservation Types
FormalinOther PreservativeDiagnoses
Not specifiedNeoplasticCarcinomaPlatforms
MorphologyH-and-E microscopyPre-analytical Factors
Classification Pre-Analytical Factor Value(s) Biospecimen Preservation Duration of tissue/ specimen processing 13 h3 h 15 minBiospecimen Preservation Temperature of fixation/preservation 67-74 degrees CRoom temperatureBiospecimen Preservation Type of fixation/preservation Formalin (buffered)Microwave irradiation