Quantitative evaluation of protein expression as a function of tissue microarray core diameter: is a large (1.5 mm) core better than a small (0.6 mm) core?
Anagnostou VK, Lowery FJ, Syrigos KN, Cagle PT, Rimm DL
Purpose
Conclusion
Studies (1)
Purpose
The purpose of this study was to determine the effects of tissue microarray core size on IHC AQUA scores for biomarkers in breast cancer, lung cancer and melanoma specimens. A randomly chosen single field of 0.6 mM was compared to a composite of several fields representing a 1 mM or 1.5 mM spot.
Summary of Findings
Correlations of 0.94 and 0.92 were observed between HER2 and ER AQUA scores for 0.6 mM fields and 1.5 mM spots on a breast cancer tissue microarray. AQUA scores for mammalian target of rapamycin (mTOR)and p70S6K in 0.6 mM fields and 1.5 mM spots of lung cancer had correlations of 0.96 and 0.98, respectively, and AQUA scores for epidermal growth factor receptor (EGFR) and signal transducer and activator of transcription 3 (STAT3) in lung cancer had correlations of 0.98 and 0.86 for 0.6 mM fields and 1.0 mM spots. When a 0.6 mM field was compared to a 1 mM spot of melanoma, correlations of 0.92 and 0.90 were observed for mTOR and p70S6K. There were no significant differences between AQUA scores of different sections of the same array.
Biospecimens
TissueLungTissueBreastTissueSkinPreservation Types
FormalinDiagnoses
NeoplasticCarcinomaNeoplasticMelanomaPlatforms
ProteinImmunohistochemistryProteinTissue microarrayPre-analytical Factors
Classification Pre-Analytical Factor Value(s) Biospecimen Acquisition Biospecimen location Breast cancerLung cancerMelanomaBiospecimen Aliquots and Components Aliquot size/volume 0.6 mm field1.0 mm spot1.5 mm spotImmunohistochemistry Specific Targeted peptide/protein EGFRER alphaHER-2/neuSTAT3mTORp70S6K