Influence of 8 and 24-h storage of whole blood at ambient temperature on prothrombin time, activated partial thromboplastin time, fibrinogen, thrombin time, antithrombin and D-dimer.
Kemkes-Matthes B, Fischer R, Peetz D
Purpose
Conclusion
Studies (1)
Purpose
The purpose of this study was to determine the effects of whole blood storage at room temperature on plasma coagulation parameters including PT, APTT, Fbg, AT, TT, and D-dimer. Aliquots from initial collection tubes were transferred to Eppendorf tubes for centrifugation after designated storage time, and plasma was subsequently analyzed. Between aliquots, collection tubes remained undisturbed except for brief manual inversion prior to the 8 and 24 h aliquot transfers. Normal and pathological specimens were analyzed.
Summary of Findings
The average percentage change after 8 and 24 h of room temperature storage was less than 10% for all coagulation parameters investigated when values at 4 h were taken as the baseline. However, some parameters did show significant changes for individual patients. PT was significantly higher after 8 h storage (2.2%), but not 24 h (5%), for 1 of the 56 specimens. APTT, Fbg, and AT showed clinically insignificant changes after 8 h of storage, but after 24 h, 6 of 51, 5 of 45, and 3 of 49 specimens showed increases of more than 15%, respectively. TT and D-dimer showed no clinically or statistically significant changes in individuals after 8 or 24 h storage, however, patients undergoing heparin treatment were excluded from TT analysis and patients with baseline D-dimer values below 0.45 mg/L fibrinogen equivalent units (FEU) were excluded from D-dimer analysis.
Biospecimens
FluidBloodFluidPlasmaPreservation Types
None (Fresh)Diagnoses
NormalNot specifiedPlatforms
MorphologyHematology/ auto analyzerProteinHematology/ auto analyzerPeptideHematology/ auto analyzerPre-analytical Factors
Classification Pre-Analytical Factor Value(s) Biospecimen Aliquots and Components Centrifugation Centrifugation delays investigatedStorage Time at room temperature 24 h4 h8 h