Studies on the quality of specimens obtained by skin puncture of children 1. Tendency to hemolysis, and hemoglobin and tissue fluid as contaminants.

Meites S, Lin SS, Thompson C

Publication: Clin Chem (1981) • Vol 27 • Page 875-8PMID: 7237767View on PubMed

Purpose

The purpose of this paper was to determine the effects of excessive squeezing during skin puncture on hemolysis, electrolyte and enzyme levels in pediatric plasma specimens.

Conclusion

The highest hemoglobin levels were found in plasma specimens taken from infants that were 0-13 days old and in this group excessive squeezing led to increased hemolysis and increased plasma potassium levels. In older infants, children, and adults, excessive squeezing did not lead to any significant effects.

Studies (1)

Purpose

The purpose of this study was to determine the effects of patient age and excessive squeezing during skin puncture on hemolysis, electrolyte and enzyme levels in plasma specimens. Lithium heparin plasma was stored frozen prior to use in this study.

Summary of Findings

The highest hemoglobin levels were found in plasma specimens taken from infants that were 0-13 days old. Aside from this age group, patient age had no influence on the levels of hemolysis in plasma specimens. Excessive squeezing during skin puncture led to significantly increased plasma potassium levels above that expected due to the incurred hemolysis and method precision in 0-13 day old infants bt not for any other age group. In adults, there was no effect of squeezing on alanine aminotransferase (ALT), aspartate aminotransferase (AST) or inorganic phosphorus and only 2 of the 86 specimens had elevated sodium levels. Slight increases in lactate dehydrogenase were noted with squeezing for all age groups, but no statistical analysis was presented.

  • Biospecimens

    FluidPlasma
    FluidBlood
  • Preservation Types

    Frozen
  • Diagnoses

    Not specified
  • Platforms

    ProteinClinical chemistry/auto analyzer
    ProteinSpectrophotometry
    Electrolyte/MetalFlame emission photometry
  • Pre-analytical Factors

    ClassificationPre-Analytical FactorValue(s)
    PreaquisitionPatient age
    0-13 days
    14 days -3 months
    2-9 years
    3 months - 2 years
    Adult
    Biospecimen AcquisitionMethod of fluid acquisition
    Finger/heel prick sampling
    Finger/heel prick with squeezing