Skip to main content

Comparative analysis of detecting monocytic cells and their aberrancy.

Dunphy CH

Publication: Appl Immunohistochem Mol Morphol (2011) • Vol 19 • Page 336-40PMID: 21293259View on PubMed

Purpose

The purpose of this paper was to compare the detection of monocytic cells (MCs) and their antigens by flow cytometry (FC), immunohistochemistry (IHC), and cytomorphology.

Conclusion

More MCs were detected by FC than by cytomorphology in 45% of cases. A high concordance between the two detection strategies was seen in 41% of cases. FC showed higher sensitivity for the detection of CD14, CD2, and CD56 than IHC. IHC detection of CD14 however, showed higher specificity for MCs than FC did, but CD163, CD68, and CD33 immunostaining showed low specificity for MCs. CD56 showed the highest correlation (93%) of immunostaining between clot and core biopsy specimens. CD123, CD163, and CD68 showed greater immunostaining in clot sections than core biopsies, which the authors hypothesize was due to decalcification.

Studies (1)

Purpose

The purpose of this study was to compare the detection of MCs in bone marrow by FC, IHC, and cytomorphology. Fresh peripheral blood specimens were also analyzed by FC.

Summary of Findings

With a total of 40 specimens analyzed, more MCs were detected by FC than by cytomorphology in 45% of cases. A high concordance between the two detection strategies was seen 41% of the time. Hemodilution was shown for 5 FC specimens. FC was more sensitive for the detection of CD14, CD2, and CD56 than IHC, but IHC detection of CD14 was more specific for MCs. On the other hand, IHC detection of CD163, CD68, and CD33 showed low specificity for MCs. CD56 showed the highest correlation (93%) of immunostaining between clot and core biopsy specimens, while CD14 and CD33 showed more moderate correlations between the two specimen types of 85% and 70%, respectively. CD123, CD163, and CD68 showed greater immunostaining in clot sections than core biopsies, which the authors hypothesize was due to decalcification.

  • Biospecimens

    TissueBone Marrow
    FluidBlood
  • Preservation Types

    FormalinOther PreservativeNone (Fresh)
  • Diagnoses

    NeoplasticLeukemia
  • Platforms

    Cell count/volumeFlow cytometry
    ProteinImmunohistochemistry
    MorphologyLight microscopy
  • Pre-analytical Factors

    ClassificationPre-Analytical FactorValue(s)
    Biospecimen AcquisitionMethod of tissue acquisition
    Aspirate
    Core needle biopsy
    Particle clot
    Biospecimen PreservationType of fixation/preservation
    Air-dried
    Formalin (buffered)
    None (fresh)
    Immunohistochemistry SpecificTargeted peptide/protein
    CD123
    CD14
    CD163
    CD2
    CD3
    CD33
    CD56
    CD68
    Flow cytometry SpecificTechnology platform
    Cytomorphology (light microscopy)
    Immunohistochemistry