Accuracy of DNA amplification from archival hematological slides for use in genetic biomarker studies.

Boyle EB, Steinbuch M, Tekautz T, Gutman JR, Robison LL, Perentesis JP

Publication: Cancer Epidemiol Biomarkers Prev (1998) • Vol 7 • Page 1127-31PMID: 9865432View on PubMed

Purpose

The purpose of this paper was to determine the effects of DNA extraction method on PCR success and DNA sequencing from stained and unstained bone marrow aspirates.

Conclusion

Proteinase k digestion did not increase DNA extraction success; however, PCR results were inconsistent when DNA was not purified by phenol-chloroform extraction or MicroTurboGen. The authors report that extraction of DNA from unstained, Wright-Giemsa-stained, or Toluidine blue-stained specimens had no effect on PCR success. Using methanol-fixed bone marrow aspirates and phenol-chloroform extraction, the artifactual mutation rate was 1 in 3384 bases. Sequencing matched frozen specimens confirmed the data from the methanol-fixed specimens.

Studies (1)

Purpose

The purpose of this study was to determine the effects of DNA extraction method on PCR amplification and DNA sequencing results from methanol-fixed stained and unstained bone marrow aspirates from patients with leukemia. The effect of methanol-fixation and storage at room temperature rather than freezing was also investigated in 2 matched specimens. Bone marrow aspirates were collected between 1967 and 1995 and stored at room temperature until use for this study.

Summary of Findings

Proteinase k digestion did not increase DNA extraction success; however, PCR results were inconsistent when DNA was not purified by phenol-chloroform extraction or MicroTurboGen. When DNA was isolated by lysis followed by phenol-chloroform extraction, amplification of one n-ras and/or k-ras locus was possible in 16 of 17 specimens. The authors report that extraction of DNA from unstained, Wright-Giemsa-stained, or Toluidine blue-stained specimens had no effect on PCR success, but note that only one Toluidine blue stained specimen was used. 10 mutations identified in the specimens by sequencing were not reproduced resulting in an artifactual mutation rate of 1 in 3384 bases. In the two cases with matched frozen specimens, sequencing of the frozen specimen confirmed the data from the methanol-fixed specimen.

  • Biospecimens

    TissueBone Marrow
  • Preservation Types

    Other PreservativeFrozen
  • Diagnoses

    NeoplasticLeukemia
    Down Syndrome
  • Platforms

    DNAPCR
    DNADNA sequencing
  • Pre-analytical Factors

    ClassificationPre-Analytical FactorValue(s)
    Biospecimen PreservationType of fixation/preservation
    Frozen
    Methanol
    Analyte Extraction and PurificationAnalyte isolation method
    Lysis in TEN with SDS
    MicroTurboGen
    None
    Phenol-chloroform
    Analyte Extraction and PurificationProtein digestion
    None
    Proteinase K
    PCR SpecificTargeted nucleic acid
    N-ras
    k-ras
    PCR SpecificType of tissue stain
    Toluidine blue
    Unstained