Stability of intact parathyroid hormone in samples from hemodialysis patients.
Cavalier E, Delanaye P, Carlisi A, Krzesinski JM, Chapelle JP
Purpose
Conclusion
Studies (1)
Purpose
The purpose of this study was to determine the effects of storage on PTH levels in EDTA-plasma and serum using the Roche Elecsys assay.
Summary of Findings
There was no difference in PTH levels between serum and EDTA-plasma with no storage or when specimens were stored at -20 degrees C for up to 24 h, but after 5 days at -20 degrees C, PTH levels in EDTA-plasma were decreased by 10.8% and serum levels were decreased by 7.2% (p<0.0004). In contrast, when specimens were stored at room temperature for 24 h, EDTA-plasma PTH levels only decreased by 4.1%, but serum levels declined by 20.5%. The authors report that the decrease in serum PTH levels after storage at room temperature would result in misclassification of 33% of patients. The authors conclude that if rapid delivery to the laboratory is not possible, specimens should be collected in EDTA tubes and analyzed within 24 h, but that EDTA-plasma should not be frozen.
Biospecimens
FluidPlasmaFluidSerumPreservation Types
None (Fresh)Diagnoses
Other diagnosesPlatforms
PeptideClinical chemistry/auto analyzerPre-analytical Factors
Classification Pre-Analytical Factor Value(s) Preaquisition Diagnosis/ patient condition Hemodialysis patientsBiospecimen Acquisition Time of biospecimen collection DecemberOctoberBiospecimen Aliquots and Components Blood and blood products PlasmaSerumStorage Storage duration 0 h24 h5 days8 hStorage Storage temperature -20 degrees CRoom temperature