Serum versus heparinized plasma for eighteen common chemistry tests: is serum the appropriate specimen?
Ladenson JH, Tsai LM, Michael JM, Kessler G, Joist JH
Purpose
Conclusion
Studies (2)
Purpose
The purpose of this study was to determine the effects of heparinized-plasma or serum on the levels of 18 clinical chemistry analytes.
Summary of Findings
Albumin, alkaline phosphatase, carbon dioxide, creatine phosphokinase, glucose, inorganic phosphorous, and potassium concentrations were higher in serum than in plasma. Calcium, chloride, lactate dehydrogenase (LDH), and total protein were higher in plasma than in serum. The authors believe the differences in calcium, glucose, inorganic phosphorous, potassium and total phosphate could be clinically relevant. When pooled serum was divided between serum and lithium heparinate tubes, no differences in analytes were found, indicating the initial differences were not caused by the presence of heparin.
Biospecimens
FluidPlasmaFluidSerumPreservation Types
None (Fresh)Diagnoses
Not specifiedPlatforms
ProteinClinical chemistry/auto analyzerSmall moleculeClinical chemistry/auto analyzerElectrolyte/MetalFlame emission photometryCarbohydrateClinical chemistry/auto analyzerSteroidClinical chemistry/auto analyzerGasClinical chemistry/auto analyzerCell count/volumeHematology/ auto analyzerPre-analytical Factors
Classification Pre-Analytical Factor Value(s) Biospecimen Aliquots and Components Blood and blood products PlasmaSerum
Purpose
The purpose of this study was to determine the effect of anticoagulants on the measurement of glucose and potassium in plasma and serum.
Summary of Findings
When specimens were collected in tubes containing lithium fluoride or sodium iodoacetate and sodium heparinate, potassium levels were 0.21 and 0.41 mEq per liter higher, respectively, than in serum. No differences between serum and plasma glucose levels were found when specimens were collected in lithium fluoride tubes. However, when specimens were collected in tubes containing sodium iodoacetate and sodium heparinate, plasma glucose levels were 5 mg/dL higher than serum levels. The authors conclude that lithium fluoride-plasma is suitable for the measurement of glucose, but that the measurement of potassium requires the use of a different anticoagulant.
Biospecimens
FluidPlasmaFluidSerumFluidBloodPreservation Types
None (Fresh)Diagnoses
Not specifiedPlatforms
CarbohydrateClinical chemistry/auto analyzerElectrolyte/MetalFlame emission photometryPre-analytical Factors
Classification Pre-Analytical Factor Value(s) Biospecimen Acquisition Anticoagulant Lithium fluorideNoneSodium heparinSodium iodoacetateBiospecimen Aliquots and Components Blood and blood products PlasmaSerum