Skip to main content

Polymerase chain reaction microanalysis of tumors from stained histological slides.

Whetsell L, Maw G, Nadon N, Ringer DP, Schaefer FV

Publication: Oncogene (1992) • Vol 7 • Page 2355-61PMID: 1279500View on PubMed

Purpose

The purpose of this paper was to determine the effects of cell capture method, PCR fragment length, storage and deparaffinization on PCR and genotype determination in stained formalin-fixed paraffin embedded (FFPE) tumors.

Conclusion

Use of a standard pipetman p20 tip or a micromanipulator to scrape cells and mineral oil to collect the scraping provided the best specimen for PCR and genotype determination. A 128 bp fragment of k-ras was amplified directly from the mineral oil-cell mixture, but efficiency improved slightly with the addition of 5 uL water (92% versus 88%). Amplification success decreased when the fragment was more than 210 bp. PCR success was lower in the specimen stored for 10 years (42%) and the specimen that was not stained or deparaffinized (38%) compared to specimens that were routinely stained and deparaffinized and not stored (88%).

Studies (1)

Purpose

The purpose of this study was to determine the effects cell capture method, PCR fragment length, storage and deparaffinization on PCR and genotype determination in stained FFPE pancreas, colorectal, lung and liver tumors.

Summary of Findings

Use of a standard pipetman p20 tip to scrape cells from a 1-2 mM area of the section or use of a micromanipulator to scrape 30-100 cells was superior to using a syringe or Pasteur pipette. Using oil to collect the scraping was superior to water, ethanol or xylene. A 128 bp fragment of k-ras was amplified directly from the mineral oil-cell mixture, but efficiency improved slightly with the addition of 5 uL water (92% versus 88%). A 260 bp fragment of h-ras was amplified in 24% of specimens with a single round of amplification and 31% when nested primers were used in a second round of amplification. Amplification success decreased when the fragment was more than 210 bp. PCR success was lower in the specimen stored for 10 years (42%) and the specimen that was not stained or deparaffinized (38%) compared to specimens that were routinely stained and deparaffinized and not stored (88%).

  • Biospecimens

    TissuePancreas
    TissueColorectal
    TissueLung
    TissueLiver
  • Preservation Types

    Formalin
  • Diagnoses

    Neoplastic
  • Platforms

    DNAPCR
  • Pre-analytical Factors

    ClassificationPre-Analytical FactorValue(s)
    Biospecimen Aliquots and ComponentsCell capture method
    Ethanol
    Micromanipulator
    Mineral oil
    Pipetman tip
    Scraping with Pasteur pipette
    Scraping with syringe
    Water
    Xylene
    StorageStorage duration
    10 years
    None
    Analyte Extraction and PurificationDeparaffinization
    None
    Xylene
    PCR SpecificLength of gene fragment
    128 bp
    174 bp
    210 bp
    260 bp
    PCR SpecificNucleic acid amplification
    Nested
    Single round
    PCR SpecificTargeted nucleic acid
    h-ras
    k-ras