Skip to main content

Assessment of morphology, antigenicity, and nucleic acid integrity for diagnostic thyroid pathology using formalin substitute fixatives.

Lassalle S, Hofman V, Marius I, Gavric-Tanga V, Brest P, Havet K, Butori C, Selva E, Santini J, Mograbi B, Hofman P

Publication: Thyroid (2009) • Vol 19 • Page 1239-48PMID: 19888862View on PubMed

Purpose

The purpose of this paper was to determine the effects of fixative type, duration and temperature on diagnosis of thyroid carcinomas.

Conclusion

Use of all fixatives allowed for histological identification of follicular carcinomas (FC), and conventional (C-PTC) or follicular variant papillary carcinomas (FV-PTC). Immunohistochemical (IHC) staining was antigen specific, but generally formalin, FineFix and RCL2 were the best fixatives. DNA and RNA quality was optimal when specimens were snap-frozen, but RCL2 worked better than the other fixatives. In general, no effects of fixation duration or temperature were found.

Studies (3)

Purpose

The purpose of this study was to determine the effects of fixative type, duration and temperature on morphological assessment of thyroid carcinomas. Specimens from four conventional papillary thyroid carcinomas, four follicular variant of papillary thyroid carcinomas, three minimally invasive follicular carcinomas, four thyroid adenomas, five thyroid nodular hyperplasias, and five normal thyroid tissues were collected after thyroidectomy (15-20 min warm ischemia). Within 30 min, 200 mg specimens were fixed for 6, 12, or 24 hours in formalin, Glyo-Fixx, FineFIX, ExcellPlus, RCL2 at room temperature or at 4˚C. Tissues were stained with hematoxylin–eosin, periodic acid Schiff, trichromic Masson, and Sweet-Gordon staining and evaluated by four blinded pathologists.

Summary of Findings

Use of all fixatives allowed for diagnosis of FC, C-PTC, and FV-PTC with H&E staining. However, specimens fixed with FineFix or RCL2 were soft and redish-brown in color when compared to specimens fixed with formalin, GlycoFixx or ExcellPlus. Specimens fixed with GlycoFixx or FineFix sectioned better than specimens fixed with RCL2 or ExcellPlus. Histologically, formalin-fixation was best though the difference was only significant when compared to RCL2 or ExcellPlus. No effect of fixation temperature or duration was found.

  • Biospecimens

    TissueThyroid Gland
  • Preservation Types

    FormalinFrozenOther Preservative
  • Diagnoses

    NeoplasticBenign
    NeoplasticNormal Adjacent
    NeoplasticCarcinoma
  • Platforms

    MorphologyLight microscopy
    MorphologyH-and-E microscopy
  • Pre-analytical Factors

    ClassificationPre-Analytical FactorValue(s)
    Biospecimen PreservationTemperature of fixation/preservation
    4 degrees C
    Room temperature
    Biospecimen PreservationTime in fixative
    12 h
    24 h
    6 h
    Biospecimen PreservationType of fixation/preservation
    ExcellPlus
    FineFIX
    Formalin (buffered)
    GlycoFixx
    RCL2
    Snap frozen