A novel microscope slide adhesive for poorly adherent tissue sections
Sompuram SR, McMahon D, Vani K, Ramanathan H, Bogen SA
Purpose
Conclusion
Studies (1)
Purpose
The purpose of this study was to determine the effects of slide adhesive on the retention of tissue sections after IHC and histological staining using several tissues which demonstrated poor slide adhesion in previous studies.
Summary of Findings
While 31/107 tissue section pairs showed equivalent adhesion (graded from 1-3) on PI- and aminosilane-coated slides, 71/107 specimen pairs demonstrated superior adhesion with the PI-coated slides. The 5 pairs of sections where adhesion to aminosilane slides was superior to PI-coated slides had not undergone antigen retrieval. The authors suggest that wet heat associated with antigen retrieval may enhance the performance of PI-coated slides. PI-coated slides were also determined to be superior to poly-L-lysine- and polysine-coated slides. In some instances, the diagnostically important area of tissue was only evident on PI-coated slides and lost from the other slides. The authors did not note any differences between tissue types.
Biospecimens
TissueBoneTissueBrainTissueMuscle (Skeletal)TissueBreastTissueBone MarrowTissueLymph NodePreservation Types
FormalinDiagnoses
Not specifiedNeoplasticCarcinomaPlatforms
ProteinImmunohistochemistryMorphologyLight microscopyPre-analytical Factors
Classification Pre-Analytical Factor Value(s) Biospecimen Acquisition Biospecimen location BoneBone marrowBrainBreastLymph nodeMuscleBiospecimen Aliquots and Components Tissue section adhesion AminosilanePoly-L-lysinePolysineProtected isocyanateAnalyte Extraction and Purification Antigen retrieval Microwave in Antigen Retrieval Citra PlusMicrowave in EDTANone