Diagnostic effect of an improved preembedding method of prostate needle biopsy specimens.
Rogatsch H, Moser P, Volgger H, Horninger W, Bartsch G, Mikuz G, Mairinger T
Purpose
The purpose of this paper was to determine the effects of stretching and orienting prostate needle biopsies prior to fixation on cancer diagnosis.
Conclusion
Stretching and orienting prostate needle biopsy specimens between two nylon meshes, in tissue cassettes, prior to fixation significantly improved the ability to diagnose prostate adenocarcinoma compared to conventional preembedding methods. Further, fewer sections were necessary to diagnose cancer than with conventional preembedding methods.
Studies (1)
Purpose
The purpose of this study was to determine the effects of stretching and orienting prostate needle biopsy specimens between two meshes, in tissue cassettes, prior to fixation, on cancer diagnosis.
Summary of Findings
Stretching and orienting prostate needle biopsy specimens between two nylon meshes, in tissue cassettes, prior to fixation resulted in significant decreases in the fractions of specimens diagnosed as benign or containing atypical foci suspicious for cancer, while the fraction diagnosed as prostate adenocarcinoma increased compared to conventional preembedding methods. Significant increases in the measured length of the core biopsies and the length of biopsy containing cancerous cells were also observed. Furthermore, with optimized preembedding techniques, the number of needle biopsies containing cancer per case increased, including a significant decrease in the number of cases with only one biopsy containing cancer. These improvements were observed using sections taken from only 1 level of the paraffin blocks for optimally preembedded specimens, compared with sections from 2-3 levels of conventionally preembedded specimens.
Biospecimens
TissueProstatePreservation Types
FormalinDiagnoses
NeoplasticCarcinomaNeoplasticBenignPlatforms
MorphologyLight microscopyMorphologyH-and-E microscopyPre-analytical Factors
Classification Pre-Analytical Factor Value(s) Biospecimen Acquisition Type of collection container/solution Free floatingStretched between nylon meshes in tissue cassetteBiospecimen Aliquots and Components Biospecimen heterogeneity Sectioned on a single planeSectioned on multiple planes