Sonification as a means of enhancing the detection of gene expression levels from formalin-fixed, paraffin-embedded biopsies.
Houze TA, Gustavsson B
Purpose
Conclusion
Studies (1)
Purpose
The purpose of this study was to determine the effects of sonification duration on beta-actin detection in FFPE colorectal carcinoma specimens.
Summary of Findings
When specimens were exposed to sonification prior to mRNA enrichment, detection of beta-actin increased with the duration of sonification. In specimens that were exposed to sonification for at least 12 sec, beta-actin was detected in FFPE tissue at similar levels as in fresh tissue.
Biospecimens
TissueColorectalPreservation Types
FormalinNone (Fresh)Diagnoses
NeoplasticCarcinomaPlatforms
RNART-PCRPre-analytical Factors
Classification Pre-Analytical Factor Value(s) Biospecimen Preservation Type of fixation/preservation Formalin (buffered)None (fresh)Analyte Extraction and Purification Cell/tissue permeabilization 0 sec12 sec15 sec3 sec6 sec9 sec