Skip to main content

Immunohistochemical detection of progesterone receptors in archival breast cancer.

Mote PA, Leary JA, Clarke CL

Publication: Biotech Histochem (1998) • Vol 73 • Page 117-27PMID: 9674881View on PubMed

Purpose

The purpose of this paper was to determine the effects of slide type, adhesive, and section thickness on section retention and antigen retrieval techniques on progesterone (PR) immunohistochemistry (IHC).

Conclusion

Heat-induced antigen retrieval was necessary for PR immunoreactivity, and autoclaving was superior to microwave pretreatment. The hPRa 7 antibody required shorter heat-induced antigen retrieval than the hPRa 6 antibody. Section loss occurred more often with section thicknesses of 4 uM compared with 2 uM. The best combination of slide and adhesive was Superfrost Plus slides with Mayer albumin.

Studies (1)

Purpose

The purpose of this study was to determine the effects of slide type, adhesive, and section thickness on section retention of breast carcinomas and antigen retrieval techniques on PR IHC in breast carcinomas and normal myometrium.

Summary of Findings

Heat-induced antigen retrieval was necessary for PR immunoreactivity, and autoclaving for 20 minutes was superior to microwave pretreatment for an equivalent amount of time (p=0.009). The hPRa 7 antibody was able to detect PR after autoclave pretreatment for 5-10 minutes and staining intensity increased after 30 minutes of antigen retrieval. However, the hPRa 6 antibody yielded only weak immunostaining after antigen retrieval of less than 20 minutes. Section loss (absent, damaged, or frayed) occurred more often with section thicknesses of 4 uM compared with 2 uM. After antigen retrieval by autoclaving for 20 minutes, significantly more sections were retained on Superfrost Plus slides than Histogrip or Silane coated slides (p=0.0001), the latter two of which performed similarly. The use of additional adhesives did not improve section retention for Histogrip slides while Para Pen and Mayer albumin each improved section retention for Silane and Superfrost Plus slides. Mayer albumin was the best adhesive, and the best combination of slide and adhesive was Superfrost Plus slides with Mayer albumin.

  • Biospecimens

    TissueBreast
    TissueUterus
  • Preservation Types

    Formalin
  • Diagnoses

    Normal
    NeoplasticCarcinoma
  • Platforms

    ProteinImmunohistochemistry
    MorphologyLight microscopy
  • Pre-analytical Factors

    ClassificationPre-Analytical FactorValue(s)
    Biospecimen Aliquots and ComponentsAliquot size/volume
    2 uM thick section
    4 uM thick section
    Biospecimen Aliquots and ComponentsTissue section adhesion
    Mayer albumin adhesive
    Para Pen
    Uncoated
    Biospecimen Aliquots and ComponentsType of slide
    Histogrip
    Silane
    Superfrost Plus
    Analyte Extraction and PurificationAntigen retrieval
    0 min
    10 min
    15 min
    20 min
    30 min
    36 min
    5 min
    Analyte Extraction and PurificationTemperature of heat-induced retrieval
    Autoclave
    Microwave
    Immunohistochemistry SpecificType of antibody
    hPRa 6
    hPRa 7