Efficiency evaluation of a DNA extraction and purification protocol on archival formalin-fixed and paraffin-embedded tissue.
Farrugia A, Keyser C, Ludes B
Purpose
Conclusion
Studies (1)
Purpose
The purpose of this study was to determine the effects of DNA extraction method on DNA yield and genetic profiling. Heart and liver tissues were collected at autopsy after a postmortem interval of up to 3 days and fixed for 28-51 days.
Summary of Findings
The highest yield was obtained when DNA was isolated using the QIAamp mini kit with the addition of a phenol-chloroform purification step after the proteinase k digestion. Significantly more DNA was extracted from liver than from heart tissue. The authors report that only partial STR profiles were obtained from the subjects because loci of more than 300 bp failed to amplify.
Biospecimens
TissueHeartTissueLiverPreservation Types
FormalinDiagnoses
AutopsyNot specifiedPlatforms
DNAFluorometryDNAPCRPre-analytical Factors
Classification Pre-Analytical Factor Value(s) Biospecimen Acquisition Biospecimen location HeartLiverAnalyte Extraction and Purification Analyte isolation method Phenol-chloroform extraction followed by CleanMax kitPhenol-chloroform followed by QIAamp DNA mini kitQIAamp DNA mini kitAnalyte Extraction and Purification Protein digestion Proteinase k digestion overnight at 48 degrees C in 100mM Tris 5 mM EDTA and 1% SDSProteinase k digestion using the QIAamp DNA mini kit