Skip to main content

Comparison of methods for DNA extraction from paraffin-embedded tissues and buccal cells.

Cao W, Hashibe M, Rao JY, Morgenstern H, Zhang ZF

Publication: Cancer Detect Prev (2003) • Vol 27 • Page 397-404PMID: 14585327View on PubMed

Purpose

The purpose of this paper was to determine the effects of extraction method on DNA quality and PCR success.

Conclusion

PCR success was highest when DNA was extracted from formalin-fixed paraffin-embedded (FFPE) specimens with phenol-chloroform or simple boiling. From fresh or frozen buccal cells, PCR success was highest when DNA was extracted using phenol-chloroform. The targeted gene had no effect on PCR success when DNA was extracted from buccal cells using phenol-chloroform. The authors report that storing buccal cells at room temperature or frozen had little effect on PCR success.

Studies (2)

Purpose

The purpose of this study was to determine the effects of DNA extraction method on DNA quality and PCR success from FFPE lung and bladder tumor specimens.

Summary of Findings

The highest average DNA yield (48.6 ug) was obtained when DNA was extracted using the simple boiling method, but the OD 260/280 ratio was only 1.13. When DNA was extracted with phenol-chloroform and the QIAamp DNA mini kit, 6 and 9 ug of DNA were obtained, respectively, and the OD 260/280 ratios were 1.79 and 1.71, respectively. When DNA was extracted by phenol-chloroform or simple boiling, a 256 bp product of beta-globin was amplified in 29 and 30 of 34 specimens, respectively. In contrast, when DNA was extracted by the QIAamp DNA mini kit, beta-globin was successfully amplified in only 18 of 34 specimens.

  • Biospecimens

    TissueBladder
    TissueLung
  • Preservation Types

    Formalin
  • Diagnoses

    Neoplastic
  • Platforms

    DNAPCR
    DNASpectrophotometry
  • Pre-analytical Factors

    ClassificationPre-Analytical FactorValue(s)
    Analyte Extraction and PurificationAnalyte isolation method
    Boiling method
    Phenol-chloroform
    QIAamp DNA mini kit