The purpose of this paper was to determine the effects of fixation technique and fixative type on a variety of surgical and postmortem tissue specimens.

Conclusion

Morphological preservation in specimens fixed by microwave oven fixation in saline or Zenker's fluid was equal or superior to that in specimens fixed by all other fixation techniques and solutions in this study. Preservation of morphological details was comparable in specimens fixed by microwave fixation in formalin and vacuum oven formalin fixation. Microwave oven fixation to a temperature of 55 degrees C and fixation at temperatures above 63 degrees C were inferior to fixation at 60 and 63 degrees C in regards to morphological preservation.

Studies (1)

Purpose

The purpose of this study was to determine the effects of fixation in a plastic tissue cassette in a microwave oven with fixation in a metal tissue cassette in a vacuum oven as well as fixative type on the morphological quality of 15 different surgical and postmortem tissue specimens, including fibrous connective tissue. After microwave fixation, 2 hours of formalin baths were eliminated from tissue processing.

Summary of Findings

Morphological details were superior in specimens fixed by microwave irradiation (60 degrees C, 80 seconds) in saline compared to those in specimens fixed by microwave irradiation in formalin or distilled water and at least equal to those specimens fixed by vacuum oven (63 degrees C, 3 hours) in formalin. Further, specimens fixed by microwave irradiation in saline did not show the shrinkage that was characteristic of the vacuum oven formalin fixation. Specimens fixed by microwave irradiation in Zenker's fluid had comparable morphology to those fixed by microwave irradiation in saline and at least equal to specimens fixed by vacuum oven in Zenker's fluid. Specimens fixed by microwave irradiation in distilled water resulted in slightly lower quality staining than those fixed by vacuum oven in formalin and showed swollen tissue and cells. Morphological details in specimens fixed by microwave irradiation in formalin were comparable to specimens fixed by vacuum oven formalin fixation with slight cellular shrinkage. Morphology in specimens fixed by microwave oven irradiation to a temperature of 60 degrees C was superior to those fixed at 55 degrees C, but fixation at temperatures above 63 degrees C resulted in fracturing artifacts during sectioning and pyknotic nuclei.

  • Biospecimens

    TissueBreast
    TissueAdipose
    TissuePlacenta
    TissueLymph Node
    TissueLung
    TissueColorectal
    TissueProstate
    TissueOvary
    TissueFallopian Tube
    TissueMuscle (Skeletal)
    TissueUterus
    TissueStomach
    TissueBrain
    TissueKidney
    TissueOther
  • Preservation Types

    FormalinOther Preservative
  • Diagnoses

    Autopsy
    Not specified
  • Platforms

    MorphologyH-and-E microscopy
  • Pre-analytical Factors

    ClassificationPre-Analytical FactorValue(s)
    Biospecimen PreservationDuration of tissue/ specimen processing
    6 h
    8 h
    Biospecimen PreservationMethod of fixative delivery
    Microwaved
    Vacuum oven
    Biospecimen PreservationTemperature of fixation/preservation
    55 degrees C
    60 degrees C
    63 degrees C
    Above 63 degrees C
    Biospecimen PreservationTime in fixative
    3 h
    80 sec
    Biospecimen PreservationType of fixation/preservation
    Formalin (buffered)
    Microwave irradiation
    Saline
    Zenker's fluid
    StorageType of storage container
    Metal tissue cassette
    Plastic tissue cassette