Rapid microwave fixation--a comparative morphometric study.
Kayser K, Stute H, Lübcke J, Wazinski U
Purpose
Conclusion
Studies (1)
Purpose
The purpose of this study was to determine the effects of microwave mediated fixation and type of fixative solution on the morphological preservation of lung and lymph node specimens.
Summary of Findings
Morphology was best preserved when lung and lymph node tissue was fixed by microwave irradiation in either Tris buffer or low concentrations of formalin (0.5% and 1%). Conventional fixation for 24 h in room temperature neutral buffered formalin (7%) resulted in less clearly defined chromatin distribution and cell boundaries. Microwave irradiation in other solutions such as methanol, ethanol, or distilled water resulted in inadequate fixation, regardless of concentration. No statistically significant differences were observed in nuclear area or minimum nuclear diameter for conventional fixation or microwave fixation in Tris buffer or 1% buffered formalin.
Biospecimens
TissueLungTissueLymph NodePreservation Types
FormalinEthanolOther PreservativeDiagnoses
NormalNeoplasticCarcinomaPlatforms
MorphologyH-and-E microscopyPre-analytical Factors
Classification Pre-Analytical Factor Value(s) Biospecimen Acquisition Biospecimen location LungLymph nodeBiospecimen Preservation Concentration of fixative 0.5% Formalin1% Formalin100% Methanol50% Methanol7% Formalin80% MethanolBiospecimen Preservation Fixative additive/buffer DMSODistilled waterMultiple concentrations evaluatedSodium chlorideTris bufferBiospecimen Preservation Method of fixative delivery ImmersionMicrowavedBiospecimen Preservation Time in fixative 2 x 3 min24 hBiospecimen Preservation Type of fixation/preservation AcetoneEthanolFormalin (buffered)GlutaraldehydeMethanol