Effect of bone decalcification procedures on DNA in situ hybridization and comparative genomic hybridization. EDTA is highly preferable to a routinely used acid decalcifier.
Alers JC, Krijtenburg PJ, Vissers KJ, van Dekken H
Purpose
The purpose of this paper was to determine the effect of decalcification agent on in situ hybridization (ISH), comparative genomic hybridization (CGH) and flow cytometry.
Conclusion
Using EDTA for decalcification allowed for clear centromereic staining by ISH, determination of DNA index (DI) by flow cytometry, and extraction of DNA suitable for CGH. In contrast, specimens decalcified by an acid-based agent produced weak or fuzzy ISH signals and DNA that was too degraded for flow cytometry or CGH analysis.
Studies (1)
Purpose
The purpose of this study was to compare the effects of acid-based (RDO) and chelating-agent (EDTA) decalcification on ISH, CGH and flow cytometry results.
Summary of Findings
While strong ISH signals were detected using centromereic probes on EDTA-decalcified specimens, RDO-decalcified specimens failed to show any signal. The authors report that there were too many nuclear debris to determine the DNA index by flow cytometry from RDO-decalcified specimens; however, EDTA-decalcified specimens showed distinct diploid and tetraploid peaks. DNA was not extracted from the RDO-treated bone, but fragments of up to 10 kB were extracted from the EDTA-decalcified specimens. Further, using EDTA-decalcified specimens, determination of loss and gain of sequences was possible by CGH.
Biospecimens
TissueBonePreservation Types
FormalinDiagnoses
AutopsyNeoplasticCarcinomaPlatforms
DNAFlow cytometryDNAIn situ hybridizationDNACGHPre-analytical Factors
Classification Pre-Analytical Factor Value(s) Analyte Extraction and Purification Decalcification solution/ duration Acid based agent (RDO)Chelating agent (10% EDTA)