Monitoring of cyclosporine blood levels from central venous lines: a misleading assay?
Busca A, Miniero R, Vassallo E, Leone L, Oddenino O, Madon E
Purpose
Conclusion
Studies (1)
Purpose
The purpose of this study was to determine effects of collection method and time of collection on CSA concentrations in blood from pediatric lymphoma and leukemia patients. The first 10 mL of blood collected from the lumen of the central venous catheter used for drug administration were discarded.
Summary of Findings
When blood was obtained from the lumen of the central venous catheter used for drug administration, CSA concentrations were higher than when blood was obtained from the second lumen (p=0.014) or from a peripheral vein (p=0.001). CSA concentrations were similar in specimens collected through the second lumen or peripheral vein. While concentrations of CSA were generally lower when blood was collected 6-12 h instead of 30 min after CSA administration, the effect of collecting through the catheter lumen used for drug administration remained.
Biospecimens
FluidBloodPreservation Types
None (Fresh)Diagnoses
NeoplasticLymphomaNeoplasticLeukemiaNeoplasticPediatricPlatforms
Small moleculeImmunoassayPre-analytical Factors
Classification Pre-Analytical Factor Value(s) Preaquisition Other drugs Cyclosporine AImmunosuppressive drugsBiospecimen Acquisition Anatomical location of blood draw Central veinPeripheral veinBiospecimen Acquisition Time of biospecimen collection 30 min after cyclosporine6-12 h after cyclosporine