Skip to main content

Blood collection techniques, heparin and quinidine protein binding.

Kessler KM, Leech RC, Spann JF

Publication: Clin Pharmacol Ther (1979) • Vol 25 • Page 204-10PMID: 759074View on PubMed

Purpose

The purpose of this paper was to determine the effects of collection and storage container, patient condition and heparin administration on the percentage of unbound quinidine in blood.

Conclusion

Blood collected into or stored in red or green stoppered Vacutainer tubes had higher concentrations of quinidine then blood collected and stored in all glass systems. Patient condition had no effect on quinidine concentration, but heparin administration, as occurs during cardiac catheterization, increased the percentage of unbound quinidine.

Studies (1)

Purpose

The purpose of this study was to determine the effects of collection and storage container, heparin sulfate administration and collection method on the percentage of unbound quinidine in blood from healthy subjects and patients with congestive heart failure, chronic renal failure, or a cardiac catheter. Blood was stored for 24 h at 4 degrees C prior to analysis.

Summary of Findings

Blood collected into or stored in red or green stoppered Vacutainer tubes for 24 h at 4 degrees C had higher concentrations of quinidine then blood collected and stored in all glass systems. There was a similar fraction of unbound quinidine in healthy control subjects and patients with congestive heart failure or chronic renal failure, but the fraction of unbound quinidine increased (p<0.0001) during cardiac catheterization. The elevation of quinidine during cardiac catheterization occurred simultaneously with heparin administration and was found both when the specimen was collected by venipuncture or through the catheter.

  • Biospecimens

    FluidBlood
  • Preservation Types

    None (Fresh)
  • Diagnoses

    Cardiovascular Disease
    Normal
    Other diagnoses
  • Platforms

    Small moleculeFluorometry
  • Pre-analytical Factors

    ClassificationPre-Analytical FactorValue(s)
    PreaquisitionDiagnosis/ patient condition
    Chronic renal failure
    Congestive heart failure
    Normal volunteer
    Biospecimen AcquisitionAnatomical location of blood draw
    Heart
    Peripheral vein
    Biospecimen AcquisitionMethod of fluid acquisition
    Cardiac catheter
    Venipuncture
    Biospecimen AcquisitionTime of biospecimen collection
    After cardiac catheterization/heparin injection
    At time of heparin injection
    Prior to heparin
    Biospecimen AcquisitionType of collection container/solution
    Glass syringe
    Green-stoppered Vacutainer
    Red-stoppered Vacutainer
    StorageType of storage container
    Glass-stoppered tube
    Green-stoppered tube
    Red-stoppered tube