ADAMTS-13 levels in fresh, stored, and solvent detergent treated plasma.
Rock G, Yousef H, Neurath D, Lu M
Purpose
Conclusion
Studies (1)
Purpose
The purpose of this study was to determine the effects of freezing, storage at room temperature, and the use of SDP or CSP on the measurement of ADAMTS-13, total protein, albumin, fibrinogen, FVIII and immunoglobulins.
Summary of Findings
Storage for 5 h at room temperature (22 degrees C) had no significant effects on levels of ADAMTS-13, albumin, fibrinogen, or FVIII in fresh frozen plasma, Vitex SDP, Octapharma SDP, or CSP, and no changes were observed in ADAMTS-13, albumin, or fibrinogen levels in normal fresh plasma after 48 hours at room temperature. However, FVIII levels decreased by 28% after fresh plasma was stored for 24 hours at room temperature (p<0.05). Prior to storage at room temperature, the Vitex SDP contained higher levels of albumin and fibrinogen than the Octapharma SDP, and total protein was higher in Vitex SDP than in the Octapharma SDP and fresh frozen plasma.
Biospecimens
FluidPlasmaPreservation Types
None (Fresh)FrozenDiagnoses
Not specifiedNormalPlatforms
ProteinWestern blotProteinClinical chemistry/auto analyzerGlycoproteinClinical chemistry/auto analyzerProteinHematology/ auto analyzerPre-analytical Factors
Classification Pre-Analytical Factor Value(s) Biospecimen Aliquots and Components Biospecimen components Cryosupernatant plasmaSolvent detergent treated plasma (Octapharma)Solvent detergent treated plasma (Vitex)Biospecimen Preservation Type of fixation/preservation FrozenNone (fresh)Storage Time at room temperature 0 h12 h2 h24 h48 h5 h72 h