Benzalkonium interference with test methods for potassium and sodium.

Koch TR, Cook JD

Publication: Clin Chem (1990) • Vol 36 • Page 807-8PMID: 2337994View on PubMed

Purpose

The purpose of this paper was to determine the effects of catheter coating on potassium and sodium measurement in serum.

Conclusion

Collection of serum through the tri-lumen central venous catheter containing tridodecylmethylammonium heparin did not interfere with the measurement of sodium or potassium. When serum was collected through the Multi Med triple lumen catheter containing benzalkonium heparin, potassium was falsely increased in the first and second specimens when measured with the Astra, Paramax or Monarch analyzers, but not the Dimension, Parallel or Spectrum. The Ektachem measurement of sodium was also elevated when in the first three serum specimens collected through the Multi Med triple lumen catheter containing benzalkonium heparin.

Studies (1)

Purpose

The purpose of this study was to determine the effects of catheter coatings, sequential collection and autoanalyzer platform on potassium and sodium measurement in serum. Commercially acquired serum was drawn through two different catheter types, and sodium and potassium levels were measured using different machines.

Summary of Findings

Collection of serum through the tri-lumen central venous catheter containing tridodecylmethylammonium heparin did not interfere with the measurement of sodium or potassium. When serum was collected through the Multi Med triple lumen catheter containing benzalkonium heparin, potassium was falsely increased in the first and second specimens when measured with the Astra, Paramax or Monarch analyzers which measure potassium in diluted serum, but not the Dimension, Parallel or Spectrum which measure potassium directly in the serum specimen. The Ektachem measurement of sodium was also elevated in the first three serum specimens collected through the Multi Med triple lumen catheter containing benzalkonium heparin.

  • Biospecimens

    FluidSerum
  • Preservation Types

    Frozen
  • Diagnoses

    Not specified
  • Platforms

    Electrolyte/MetalClinical chemistry/auto analyzer
  • Pre-analytical Factors

    ClassificationPre-Analytical FactorValue(s)
    Biospecimen AcquisitionType of collection container/solution
    Multi Med triple lumen catheter containing benzalkonium heparin
    Tri-lumen central venous catheter containing tridodecylmethylammonium heparin
    Biospecimen Aliquots and ComponentsAliquot sequential collection
    10th collection
    1st collection
    2nd collection
    3rd collection
    4th collection
    5th collection
    6th collection
    7th collection
    8th collection
    9th collection
    Biospecimen Aliquots and ComponentsBiospecimen components
    Diluted serum
    Undiluted serum
    Clinical chemistry/auto analyzer SpecificDetection method
    Flame photometry
    Ion selective electrode
    Clinical chemistry/auto analyzer SpecificTechnology platform
    Abbot Spectrum
    American Monitor Parallel
    Baxter Paramax
    Beckman Astra-8
    Du Pont Dimension
    Instrumentation laboratory Monarch
    Kodak Ektachem 70