Therapeutic monitoring of cyclosporine following pediatric bone marrow transplantation: problems with sampling from silicone central venous lines.

Leson CL, Bryson SM, Giesbrecht EE, Saunders EF

Publication: DICP (1989) • Vol 23 • Page 300-3PMID: 2658375View on PubMed

Purpose

The purpose of this paper was to determine the effects of blood collection method on observed cyclosporine concentrations in blood.

Conclusion

When cyclosporine was administered through intravenous (iv) line, blood obtained through central venous lines (CVL) had 1.3-2.9 fold higher cyclosporine levels than peripheral capillary specimens, however, specimen collection method had no effect on the measurement of cyclosporine when the antibiotic was administered orally.

Studies (1)

Purpose

The purpose of this study was to determine the effects of blood collection method on cyclosporine concentrations in pediatric leukemia and blackfan diamond anemia patients.

Summary of Findings

When cyclosporine was administered through iv line, blood obtained through CVL had 1.3-2.9 fold higher cyclosporine levels than peripheral capillary specimens, however, specimen collection method had no effect on the measurement of cyclosporine when the antibiotic was administered orally. The authors conclude that there is a problem with adsorption of cyclosporine by the silicone in the CVL during drug administration.

  • Biospecimens

    FluidBlood
  • Preservation Types

    None (Fresh)
  • Diagnoses

    NeoplasticLeukemia
    NeoplasticPediatric
    Other diagnoses
  • Platforms

    Small moleculeHPLC
  • Pre-analytical Factors

    ClassificationPre-Analytical FactorValue(s)
    PreaquisitionDiagnosis/ patient condition
    Blackfan diamond anemia
    PreaquisitionOther drugs
    IV cyclosporine
    Oral cyclosporine
    Biospecimen AcquisitionAnatomical location of blood draw
    Central vein
    Peripheral capillary