Soluble urokinase plasminogen activator receptor measurements: influence of sample handling.
Riisbro R, Christensen IJ, Høgdall C, Brünner N, Høgdall E
Purpose
Conclusion
Studies (1)
Purpose
The purpose of this study was to determine the effects of storage temperature, duration, and freeze-thaw cycling on suPAR concentration in EDTA plasma and serum. Whole blood was subjected to different storage conditions prior to centrifugation. Separated plasma and serum specimens were stored at -80 degrees C prior to analysis.
Summary of Findings
In general, levels of suPAR were higher in serum than in EDTA plasma. The concentrations of suPAR in serum or EDTA plasma were not affected by storage of whole blood at 4 or 20 degrees C for 24 hours prior to centrifugation. However, suPAR concentrations increased significantly in EDTA plasma and in serum when whole blood was stored at 20 degrees C, but not 4 degrees C, for 72 hours prior to centrifugation (p=0.009 and p=0.005, respectively). Freeze-thaw cycling had no effect on EDTA plasma or serum concentrations of suPAR.
Biospecimens
FluidBloodFluidPlasmaFluidSerumPreservation Types
FrozenDiagnoses
NormalPlatforms
ProteinELISAPre-analytical Factors
Classification Pre-Analytical Factor Value(s) Biospecimen Acquisition Anticoagulant EDTANoneBiospecimen Aliquots and Components Blood and blood products PlasmaSerumWhole bloodBiospecimen Aliquots and Components Centrifugation Centrifugation delays investigatedStorage Freeze/thaw cycling 1 cycle2 cycles3 cycles4 cycles5 cycles6 cycles7 cycles8 cyclesStorage Storage duration 1 h24 h3 h72 h8 hStorage Storage temperature 20 degrees C4 degrees C