Skip to main content

A comparison of hard and soft glass blood-drawing tubes.

Laessig RH, Hassemer DJ, Hoffman GL, Westgard JO, Carey RN, Feldbruegge DH

Publication: Am J Clin Pathol (1979) • Vol 72 • Page 952-5PMID: 517461View on PubMed

Purpose

The purpose of this paper was to determine the effects of collection tube type and storage on serum clinical chemistry analytes.

Conclusion

The use of hard or soft glass disposable evacuated blood-drawing tubes had no clinically significant effects on 34 clinical chemistry analytes using 66 different methods of analysis. In addition, there were no clinically or statistically significant differences in analyte levels between specimens refrigerated for 72 h in the two types of glass tubes.

Studies (1)

Purpose

The purpose of this study was to determine the effects of collection tube type and storage on serum clinical chemistry analytes.

Summary of Findings

The use of hard or soft glass disposable evacuated blood-drawing tubes had no clinically significant effects on 34 clinical chemistry analytes using 66 different methods of analysis. However, in four cases, small but statistically significant differences between the tube types were observed including differences in triglycerides, unsaturated iron-binding capacity, uric acid, and inorganic phosphorus. Repeat analysis of uric acid and inorganic phosphorus by other methods did not detect differences. In addition, there were no clinically or statistically significant differences in analyte levels between specimens refrigerated for 72 h in the two types of glass tubes.

  • Biospecimens

    FluidSerum
    FluidBlood
  • Preservation Types

    None (Fresh)
  • Diagnoses

    Not specified
  • Platforms

    Electrolyte/MetalClinical chemistry/auto analyzer
    Small moleculeClinical chemistry/auto analyzer
    CarbohydrateClinical chemistry/auto analyzer
    SteroidClinical chemistry/auto analyzer
    ProteinClinical chemistry/auto analyzer
    LipidClinical chemistry/auto analyzer
    Electrolyte/MetalFlame emission photometry
    Electrolyte/MetalColorimetric assay
    PeptideRadioimmunoassay
    Small moleculeRadioimmunoassay
    SteroidRadioimmunoassay
    GlycoproteinRadial immunodiffusion assay
    ProteinRadial immunodiffusion assay
    Electrolyte/MetalAtomic absorption spectroscopy
  • Pre-analytical Factors

    ClassificationPre-Analytical FactorValue(s)
    Biospecimen AcquisitionType of collection container/solution
    Hard glass evacuated blood-drawing tubes
    Soft glass evacuated blood-drawing tubes
    StorageStorage duration
    72 h
    Less than 60 min
    StorageStorage temperature
    Refrigerated
    Clinical chemistry/auto analyzer SpecificTechnology platform
    AutoAnalyzer I
    BASIC
    DuPont ACA
    SMAC