Facilitated determination of ionized calcium.
Urban P, Buchmann B, Scheidegger D
Purpose
Conclusion
Studies (1)
Purpose
The purpose of this study was to determine the effects of heparin brand and storage on Ca levels in whole blood, serum and plasma.
Summary of Findings
There were no differences between the mean concentrations of Ca in whole blood anticoagulated with heparin and serum. When Ca free heparin was used as an anticoagulant, mean Ca concentrations in plasma were more than 20% lower than in serum and decreased with higher concentrations of anticoagulant. Significant, but clinically irrelevant differences were found between brands of Ca-free heparin. Compared to specimens analyzed immediately, a slight increase in whole blood Ca was found when the specimens were stored at room temperature for 2 h, but not when stored on ice.
Biospecimens
FluidBloodFluidPlasmaFluidSerumPreservation Types
None (Fresh)Diagnoses
NormalNot specifiedPlatforms
Electrolyte/MetalIon selective electrodePre-analytical Factors
Classification Pre-Analytical Factor Value(s) Biospecimen Acquisition Anticoagulant Calcium-free heparinHeparinBiospecimen Aliquots and Components Blood and blood products PlasmaSerumWhole bloodStorage Storage duration 0 h2 hStorage Storage temperature On iceRoom temperaure