Ethylbenzene and xylene from Sarstedt Monovette serum gel blood-collection tubes.

Streete PJ, Flanagan RJ

Publication: Clin Chem (1993) • Vol 39 • Page 1344-5PMID: 8504548View on PubMed

Purpose

The purpose of this paper was to determine the source of ethylbenzene and xylene contamination of whole blood.

Conclusion

Storage of blood at room temperature for 96 h in Monovette tubes resulted in measureable levels of o-xylene, ethylbenzene, and m-xylene. The magnitude of the increase was dependent on the age of the tubes with tubes furthest from expiration having the largest effect.

Studies (1)

Purpose

The purpose of this study was to determine the effects of storing blood in Starstedt Monovette tubes on the quantification of ethylbenzene and xylene. Expired volatile-free hemolyzed blood-bank whole blood was used for all assays.

Summary of Findings

Storage of blood at room temperature for 96 h in Monovette tubes resulted in measureable levels of o-xylene, ethylbenzene, and m-xylene. The magnitude of the increase was dependent on the age of the tubes with tubes furthest from expiration having the largest effect. The authors report that Starstedt Monovette serum gel tubes, and Becton Dickinson Vacutainer STT gel and clot activator tubes do not cause an increase in the concentration of volatiles.
  • Biospecimens

    FluidBlood
  • Preservation Types

    Frozen
  • Diagnoses

    Normal
  • Platforms

    Small moleculeHeadspace gas chromatography
  • Pre-analytical Factors

    ClassificationPre-Analytical FactorValue(s)
    StorageTime at room temperature
    120 h
    24 h
    96 h
    StorageType of storage container
    Starstedt Monovette serum gel tube