Skip to main content

Protein detection in dried blood by surface-enhanced laser desorption/ionization-time of flight mass spectrometry (SELDI-TOF MS).

Dammann CE, Meyer M, Dammann O, von Neuhoff N

Publication: Biol Neonate (2006) • Vol 89 • Page 126-32PMID: 16210847View on PubMed

Purpose

The purpose of this paper was to determine the effects of preservation method, anticoagulant, and type of array on SELDI-TOF mass spectrometry (MS) of cord blood specimens.

Conclusion

Dried blood protein profiles in the 6-9 kDa region were similar to serum specimens that had been frozen, but frozen serum had more peaks visible in the 4-6 kDa range. The authors report that the use of heparin led to higher peak intensities for dried blood specimens and frozen whole blood compared to native, citrate, or EDTA blood. Good overlay of prominent peaks from frozen and dried heparinized blood specimens was noted. Heparinized dried blood specimens showed several higher peak intensities on the Q10 and CM10 arrays compared to frozen heparinized blood. The authors report that very different spectra were obtained from frozen and dried heparinized blood specimens when H50 arrays were used.

Studies (1)

Purpose

The purpose of this study was to determine the effects of preservation method, anticoagulant, and type of ProteinChip array on SELDI-TOF MS proteomic analysis.

Summary of Findings

Protein extracted from dried cord blood with U9 buffer gave a greater number of peaks and higher peak intensity compared with proteins extracted with PBS or 5% acetonitrile. Dried blood protein profiles in the 6-9 kDa range were similar to serum specimens that had been frozen, but frozen serum had more peaks visible in the 4-6 kDa range. The authors report that the use of heparin led to higher peak intensities for dried blood specimens and frozen whole blood compared to native, citrate, or EDTA blood. Heparinized dried blood showed higher peak intensities in the 2-4 kDa range compared to heparinized whole blood that was frozen however, good overlay of prominent peaks was noted. For hemoglobin depleted specimens, binding buffer at a pH of 7.5 gave the most peaks on the CM10 arrays when compared to binding buffer at a pH of 4.0. Heparinized dried blood specimens showed several higher peak intensities on the Q10 and CM10 arrays compared to frozen heparinized blood. The authors report that very different spectra were obtained from frozen and dried heparinized blood specimens when H50 arrays were used.

  • Biospecimens

    FluidSerum
    FluidCord Blood
  • Preservation Types

    FrozenOther Preservative
  • Diagnoses

    Normal
  • Platforms

    PeptideSELDI-TOF MS
    ProteinSELDI-TOF MS
  • Pre-analytical Factors

    ClassificationPre-Analytical FactorValue(s)
    PreaquisitionPatient age
    Newborn
    Biospecimen AcquisitionAnticoagulant
    Citrate
    EDTA
    Heparin
    None
    Biospecimen Aliquots and ComponentsBlood and blood products
    Serum
    Whole blood
    Biospecimen PreservationType of fixation/preservation
    Air-dried
    Frozen
    Analyte Extraction and PurificationAnalyte isolation method
    5% acetonitrile extraction buffer
    PBS extraction buffer
    U9 extraction buffer
    SELDI-TOF MS SpecificResin
    IMAC-Ni Resin for hemoglobin depletion
    No hemoglobin depletion
    SELDI-TOF MS SpecificType of array
    CM10
    H50
    Q10