Skip to main content

Magnesium contamination from Terumo blood collection tubes.

Dimeski G, Carter A

Publication: Clin Chem (2006) • Vol 52 • Page 1612-4PMID: 16873304View on PubMed

Purpose

The purpose of this paper was to determine the effects of collection tube type on magnesium (Mg) levels in serum and plasma.

Conclusion

When lithium-heparin plasma or serum was collected in Terumo VENOSAFE tubes, Mg concentrations were significantly higher than concentrations in the corresponding Becton Dickinson (BD) or Greiner tubes.

Studies (1)

Purpose

The purpose of this study was to determine the effects of collection tube type on Mg levels in serum and plasma.

Summary of Findings

When lithium-heparin plasma or serum was collected in Terumo VENOSAFE tubes, Mg concentrations were significantly higher than concentrations in the corresponding BD or Greiner tubes. The authors suggest Terumo tubes contain Mg and not an interfering substance.

  • Biospecimens

    FluidPlasma
    FluidSerum
    FluidBlood
  • Preservation Types

    None (Fresh)
  • Diagnoses

    Not specified
  • Platforms

    Electrolyte/MetalClinical chemistry/auto analyzer
  • Pre-analytical Factors

    ClassificationPre-Analytical FactorValue(s)
    Biospecimen AcquisitionAnticoagulant
    Lithium heparin
    None
    Biospecimen AcquisitionType of collection container/solution
    BD PSTII
    BD SSTII
    Greiner
    Terumo VENOSAFE
    Biospecimen Aliquots and ComponentsBlood and blood products
    Plasma
    Serum