Magnesium contamination from Terumo blood collection tubes.
Dimeski G, Carter A
Purpose
The purpose of this paper was to determine the effects of collection tube type on magnesium (Mg) levels in serum and plasma.
Conclusion
When lithium-heparin plasma or serum was collected in Terumo VENOSAFE tubes, Mg concentrations were significantly higher than concentrations in the corresponding Becton Dickinson (BD) or Greiner tubes.
Studies (1)
Purpose
The purpose of this study was to determine the effects of collection tube type on Mg levels in serum and plasma.
Summary of Findings
When lithium-heparin plasma or serum was collected in Terumo VENOSAFE tubes, Mg concentrations were significantly higher than concentrations in the corresponding BD or Greiner tubes. The authors suggest Terumo tubes contain Mg and not an interfering substance.
Biospecimens
FluidPlasmaFluidSerumFluidBloodPreservation Types
None (Fresh)Diagnoses
Not specifiedPlatforms
Electrolyte/MetalClinical chemistry/auto analyzerPre-analytical Factors
Classification Pre-Analytical Factor Value(s) Biospecimen Acquisition Anticoagulant Lithium heparinNoneBiospecimen Acquisition Type of collection container/solution BD PSTIIBD SSTIIGreinerTerumo VENOSAFEBiospecimen Aliquots and Components Blood and blood products PlasmaSerum