Purpose
The purpose of this study was to determine the effects of collection tube type on serum levels of therapeutic drugs. Patient blood was collected in syringes, transferred to the different tubes, and inverted ten times prior to serum separation and freezing.
Summary of Findings
Collection tube type did not effect ethosuximide, phenobarbital, phenytoin, valproic acid, digitoxin, digoxin, procainamide, N-acetylprocainamide, gentamicin or theophylline levels in serum. Further, all drug levels remained within the normal therapeutic range, regardless of tube type. When serum was collected in red stoppered Monoject tubes, significantly lower carbamazepine (p<0.01) and disopyramide (p<0.05) levels were found compared to specimens collected in glass tubes. Guinidine levels were significantly lower in serum collected in red stoppered Vacutainer (p<0.001) or Monoject tubes (p<0.02) than in serum collected in glass tubes. No significant differences were found when serum was collected in blue stoppered Vacutainer tubes or red stoppered Venoject tubes in comparison to serum collected in glass tubes.
Biospecimens
FluidSerumFluidBloodPreservation Types
FrozenDiagnoses
Not specifiedPlatforms
Small moleculeHPLCSmall moleculeRadioimmunoassaySmall moleculeFluorometrySmall moleculeImmunoassaySmall moleculeGC- flame ionizationPre-analytical Factors
Classification Pre-Analytical Factor Value(s) Biospecimen Acquisition Type of collection container/solution Blue stoppered VacutainerOpen glass tubeRed stoppered MonojectRed stoppered VacutainerRed stoppered Venoject