Skip to main content

Impact of the blood collection tube on the activation of coagulation.

Polack B, Barro C, Pernod G, Bourgeat P, Vigier JP

Publication: Thromb Haemost (1997) • Vol 77 • Page 217-8PMID: 9031478View on PubMed

Purpose

The purpose of this paper was to determine the effects of collection tube and anticoagulant on Factor VIIA (FVIIA) levels in plasma.

Conclusion

Fresh or frozen plasma specimens collected in Vacutainer tubes with citrate or DIATUBE-H and Venoject tubes with citrate had statistically equivalent FVIIA levels. In contrast, collection of plasma in Terumo Venoject DIATUBE-H tubes rather than Vacutainer citrate tubes resulted in significant effects on FVIIA levels.

Studies (1)

Purpose

The purpose of this study was to determine the effects of collection tube and anticoagulant on FVIIA levels in fresh and frozen plasma. Frozen specimens were analyzed at a different site.

Summary of Findings

Fresh or frozen plasma specimens collected in Vacutainer tubes with citrate or DIATUBE-H and Venoject tubes with citrate had statistically equivalent FVIIA levels, but a wider dispersion and a trend toward a positive bias were noted in specimens collected in the Venoject tubes with citrate. Collection of plasma in Terumo Venoject DIATUBE-H tubes rather than Vacutainer citrate tubes resulted in significant effects on FVIIA levels.

  • Biospecimens

    FluidPlasma
    FluidBlood
  • Preservation Types

    None (Fresh)Frozen
  • Diagnoses

    Not specified
  • Platforms

    ProteinHematology/ auto analyzer
  • Pre-analytical Factors

    ClassificationPre-Analytical FactorValue(s)
    Biospecimen AcquisitionAnticoagulant
    Citrate
    DIATUBE-H
    Biospecimen AcquisitionType of collection container/solution
    Becton Dickinson Vacutainer
    Terumo Venoject
    Biospecimen PreservationType of fixation/preservation
    Frozen
    None (fresh)