Influence of tube type on the antiglobulin test.

Black D, Kay J

Publication: Med Lab Sci (1986) • Vol 43 • Page 169-73PMID: 3736368View on PubMed

Purpose

The purpose of this paper was to determine the effect of tube type, kit, centrifugation speed and antibody on anti-human globulin reactions (AHG) in red blood cells.

Conclusion

Generally the strongest AHG reactions were observed with Generally the strongest AHG reactions were observed with the IMMUNO reagents and the weakest with the Blood Group Reference Laboratory (BGRL) reagents. Regardless of reagent source and antibody, AHG reactions increased with faster centrifugation and when the reaction occurred in glass rather than in plastic tubes. The decreased reaction in plastic tubes was found to be due to diminished anti-immunoglobulin G (anti-IgG) activity and not a change in anti-C3 activity. The effect was reduced as the concentration of antibody increased, but only occurred when both washing and the reaction were done in the plastic tube.

Studies (1)

Purpose

The purpose of this study was to determine the effects of tube type, reagent source, centrifugation speed (400 x g versus 1000 x g) and antibody on AHG in red blood cells.

Summary of Findings

Generally the strongest AHG reactions were observed with the IMMUNO reagents and the weakest with the Blood Group Reference Laboratory (BGRL) reagents. Regardless of reagent source and antibody, AHG reactions increased with faster centrifugation and when the reaction occurred in glass rather than in plastic tubes. The decreased reaction in plastic tubes was found to be due to diminished anti-immunoglobulin G (anti-IgG) activity and not a change in anti-C3 activity. The effect was reduced as the concentration of antibody increased, but only occurred when both washing and the reaction were done in the plastic tube.

  • Biospecimens

    CellRed Blood Cells
  • Preservation Types

    None (Fresh)
  • Diagnoses

    Not specified
  • Platforms

    ProteinAntiglobulin test
    ProteinMacroscopic observation
  • Pre-analytical Factors

    ClassificationPre-Analytical FactorValue(s)
    Biospecimen Aliquots and ComponentsCentrifugation
    Multiple speeds compared
    StorageType of storage container
    Glass
    Plastic
    Antiglobulin test SpecificAntibody dilution/concentration
    1:100 anti-IgG
    1:50 anti-IgG
    1:75 anti-IgG
    1:80 anti-IgG
    Antiglobulin test SpecificTargeted peptide/protein
    Anti-C3
    Anti-D
    Anti-Fy
    Anti-IgG
    Anti-Jk
    Anti-K
    Anti-Le
    Anti-S
    Anti-c
    Anti-s
    Antiglobulin test SpecificTechnology platform
    Blood Group Reference Laboratory
    IMMUNO
    Scottish Antibody Production Unit