Cold storage of citrated whole blood induces drastic time-dependent losses in factor VIII and von Willebrand factor: potential for misdiagnosis of haemophilia and von Willebrand disease.

Böhm M, Täschner S, Kretzschmar E, Gerlach R, Favaloro EJ, Scharrer I

Publication: Blood Coagul Fibrinolysis (2006) • Vol 17 • Page 39-45PMID: 16607078View on PubMed

Purpose

The purpose of this paper was to determine the effects of storage of whole blood and plasma on von Willebrand factor:ristocetin cofactor activity (VWF:RCo), von Willebrand factor:antigen (VWF:Ag), factor VIII coagulation activity (FVIII:C), and analysis of von Willebrand factor multimers (VWF multimers).

Conclusion

In healthy individuals and patients with suspected type 1 or type 2N von Willebrand disease (VWD), VWF:RCo, VWF:Ag, and FVIII:C decreased after whole blood was stored on ice for 6 hours. FVIII:C was significantly decreased for all storage conditions when compared to control specimens stored at room temperature for 3 hours as whole blood. Much smaller decreases were seen in VWF:Ag, and FVIII:C with cold storage of whole blood from patients with type 2A and 2B VWD. Storage of platelet-rich plasma from healthy individuals for 3 hours on crushed ice caused significant decreases in VWF:RCo, VWF:Ag, and FVIII:C, similar to storage of whole blood on ice. Preferential loss of intermediate and large VWF multimers was seen after cold storage of whole blood.

Studies (1)

Purpose

The purpose of this study was to determine the effects of storage of whole blood or separated plasma on crushed ice or at room temperature on VWF:RCo, VWF:Ag, FVIII:C, and VWF multimers. All specimens were frozen at -20 degrees C prior to analysis. Blood was anticoagulated with sodium citrate.

Summary of Findings

In healthy individuals and patients with suspected type 1 VWD, VWF:RCo, VWF:Ag, and FVIII:C decreased by 65, 44, and 46%, respectively after whole blood was stored on ice for 6 hours. VWF:RCo and VWF:Ag were not significantly affected when either whole blood or plasma was stored at room temperature or when plasma was stored on ice. However, FVIII:C was significantly decreased for all storage conditions when compared to control specimens stored for 3 hours at room temperature as whole blood. The decrease in FVIII:C was greatest for specimens stored as whole blood on ice. Specimens from patients with type 2N VWD exhibited decreases in VWF:RCo, VWF:Ag, and FVIII:C similar to healthy individuals and those with suspected type 1 VWD after 6 hour cold storage of whole blood. However, much smaller decreases were seen in VWF:Ag, and FVIII:C (0-28 and 0-16%, respectively) under the same storage conditions for patients with type 2A and 2B VWD (undetectable VWF:RCo). Storage of platelet-rich plasma from healthy individuals for 3 hours on crushed ice caused significant decreases in VWF:RCo, VWF:Ag, and FVIII:C, similar to storage of whole blood on ice. Preferential loss of intermediate and large VWF multimers was seen after cold storage of whole blood from a healthy individual and a patient with suspected type 1 VWD. A patient with type 2 VWD, lacking large and intermediate multimers, exhibited loss of the largest multimers that were present at room temperature after cold storage of whole blood.

  • Biospecimens

    FluidBlood
    FluidPlasma
  • Preservation Types

    Frozen
  • Diagnoses

    Normal
    Other diagnoses
  • Platforms

    ProteinHematology/ auto analyzer
    MorphologyHematology/ auto analyzer
    ProteinWestern blot
    ProteinImmunoassay
  • Pre-analytical Factors

    ClassificationPre-Analytical FactorValue(s)
    PreaquisitionDiagnosis/ patient condition
    Confirmed type 2 von Willebrand disease
    Suspected type 1 von Willebrand disease
    Biospecimen Aliquots and ComponentsBlood and blood products
    Platelet-poor plasma
    Platelet-rich plasma
    Whole blood
    Biospecimen Aliquots and ComponentsCentrifugation
    Centrifugation delays investigated
    StorageStorage duration
    3 h
    6 h
    StorageStorage temperature
    -20 degrees C
    Crushed ice
    Room temperature